Lightweight Frequency-Gated Enhancement of nnU-Net Improves Data Efficiency in Nasal Sinus CT Segmentation
Chen, Y.-C.; Wan, S.-Y.
Show abstract
Background and Objectives: Automatic segmentation of the nasal cavity and paranasal sinuses from CT aids diagnosis and surgical planning, but clinical datasets in this domain remain small, which can affect training stability and evaluation validity. This study investigates whether the frequency-domain mechanisms of the Adaptive Frequency-Spatial Dual-Stream Network (AFS-DSN) can be transferred, in a lightweight form, into the self-configuring nnU-Net framework, and whether the resulting performance improvement survives rigorous statistical validation. We integrated the AFS-DSN frequency branch and cross-domain attention mechanism into nnU-Net, and corrected a zero-initialization gating deadlock in the original design, using the corrected model (v2) as a common base. On this base, we evaluated three variants: X1, an input-conditioned learnable spectral gate applied to 24 wavelet sub-bands; X2, which adds a boundary-distance training objective; and X3, combining X1 and X2. Experiments used the 130-volume NasalSeg CT dataset, under a full 91/19/20 protocol and a rebuilt, genuine 3-fold cross-validation in which the training set for each fold was reduced by approximately 19%, from 91 to 73-74 cases. Under the full protocol, all variants showed a small but statistically detectable improvement over a matched nnU-Net baseline. X3 achieved a Dice score of 95.78% versus 95.59% for the baseline, an improvement of 0.19 percentage points (95% CI [0.09, 0.29]; Holm-adjusted p = 0.004), and X3 also reduced average surface distance (ASD) from 0.252 mm to 0.235 mm. X3 was statistically equivalent to either individual component within a margin of +/-0.10 percentage points, suggesting a shared performance ceiling rather than a complementary gain. Under reduced training data, baseline Dice dropped by 2.71 percentage points (95.59% to 92.88%), while X3 remained essentially unchanged (95.78% to 95.75%), a cross-fold advantage of +2.88 percentage points (fold-level 95% CI [0.80, 4.96]) that held across all 20 test cases (sign test, p = 1.9e-6) and was corroborated by average surface distance. The practical value of this combined approach lies primarily in within-distribution data efficiency, rather than in maximizing peak segmentation accuracy.
Matching journals
The top 9 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Dual Adversarial Deconfounding Autoencoder for joint batch-effects removal from multi-center and multi-scanner radiomics data 94%
- Assisting Scalable Diagnosis Automatically via CT Images in the Combat against COVID-19 92%
- Generating synthetic data in digital pathology through diffusion models: a multifaceted approach to evaluation 92%
Similar papers in this journal
Similar papers in this journal
- BioFuse: An Embedding Fusion Framework for Biomedical Foundation Models 93%
- Enhancing Semantic Segmentation in Chest X-Ray Images through Image Preprocessing: ps-KDE for Pixel-wise Substitution by Kernel Density Estimation 93%
- Deep learning models for COVID-19 chest x-ray classification: Preventing shortcut learning using feature disentanglement 93%
Similar papers in this journal
Similar papers in this journal
- Non-Gaussian Normative Modelling With Hierarchical Bayesian Regression 91%
- Automated quality control of T1-weighted brain MRI scans for clinical research: methods comparison and design of a quality prediction classifier 91%
- Stacking models of brain dynamics improves prediction of subject traits in fMRI 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.