Magnetic Resonance Elastography of Regional Aortic Mechanics and True- and False-Lumen Stiffness in Aortic Dissection: A Feasibility Study
Hirad, A. A.; Dong, H.; Nanjappa, M.; Kedwai, B.; Thompson, K.; Kruger, J.; Chen, J.; Kolipaka, A.; Mix, D.
Show abstract
Objective Regional aortic mechanics and the mechanical environments of the true and false lumens are not represented by maximal diameter alone. We evaluated whether magnetic resonance elastography (MRE) could provide paired descending thoracic and abdominal aorta stiffness estimates and separate true- and false-lumen estimates in thoracic aortic dissection. Methods We acquired 60-Hz descending thoracic and abdominal aortic MRE data in 10 healthy subjects and in 2 patients with chronic type B aortic dissections. Three motion-encoding directions and four temporal offsets were reduced to first-harmonic complex wave fields. After directional filtering, we traced a curved centerline through the aortic mask. Local spatial frequency was estimated along arc length and converted to effective shear stiffness. The primary regional outcome was the mean effective stiffness over the central 20%-90% of the path from the quality-ranked slice in each region. In dissection, the whole-aorta mask and flap were defined on a registered sagittal scout; a vascular surgeon assigned the true and false lumens, and separate, manually centered lumen paths followed one union-mask phase correction and unwrapping step. We compared regional values with paired tests. Results All 10 regional datasets and all 56 available slices were processed without failure. The 10 healthy volunteers (mean age, 26.6 +/- 4.6 years; 6 men) had descending thoracic stiffness of 15.43 +/- 3.30 kPa and abdominal stiffness of 19.20 +/- 3.14 kPa. The mean thoracic-minus-abdominal difference was -3.77 +/- 3.40 kPa (95% confidence interval, -6.20 to -1.34 kPa; paired t-test, P=.007; exact Wilcoxon signed-rank test, P=.010). Eight participants had a higher abdominal value, and two had a higher thoracic value. In Subject A with a chronic aortic dissection, slice-averaged true- and false-lumen stiffness was 21.62 and 19.07 kPa, respectively (false-minus-true, -2.54 kPa; absolute percentage difference, 12.5%). In Subject B with a chronic aortic dissection, corresponding values were 12.17 and 17.40 kPa (false-minus-true, +5.22 kPa; 35.3%). Conclusions We demonstrated the feasibility of MRE to provide paired regional analysis of the aorta in healthy people and to separate stiffness profiles of the true and false lumens in Type B thoracic dissection cases. Abdominal effective stiffness exceeded descending thoracic stiffness in the volunteer cohort. Opposite true- and false-lumen contrast in the two subjects with chronic Tye B aortic dissections demonstrates measurement feasibility but does not establish a consistent compartment pattern, disease threshold, or intrinsic wall material property.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Reproducibility of 4D Flow MRI-based Personalized Cardiovascular Models; Inter-sequence, Intra-observer, and Inter-observer variability 94%
- Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT 94%
- Reduced stress perfusion in myocardial infarction with nonobstructive coronary arteries 93%
Similar papers in this journal
- Strain patterns with ultrasound for improved assessment of abdominal aortic aneurysm vessel wall biomechanics 96%
- Validation of Left Ventricular High Frame Rate Echo-Particle Image Velocimetry against 4D Flow MRI in Patients 94%
- Indexing Cerebrovascular Health Using TranscranialDoppler Ultrasound 92%
Similar papers in this journal
Similar papers in this journal
- Development of a Novel Index to Characterise Arterial Dynamics Using Ultrasound Imaging 95%
- {-}CardiOvascular examination in awake Orangutans (Pongo pygmaeus pygmaeus): Low-stress Echocardiography including Speckle Tracking imaging (the COOLEST method) 92%
- Full-field optical coherence tomography for the diagnosis of giant cell arteritis 92%
Similar papers in this journal
- Non-Invasive Scale Measurement of Cardiac Output Compared with the Gold-Standard Direct Fick Method: A Feasibility Study 91%
- Disordered balance of T cell subsets in arterial tertiary lymphoid organs in immunoglobulin G4-related vascular disease 90%
- The HeartMagic prospective observational study protocol - characterizing subtypes of heart failure with preserved ejection fraction 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.