Dual-wavelength time-of-flight interferometric speckle-contrast optical spectroscopy (dual-wavelength TOF-iSCOS) for co-registered blood-flow and hemoglobin sensing
Nowacka-Pieszak, K.; Marzejon, M.; Mogharari, N.; Borycki, D.
Show abstract
Diffuse optical measurements of blood flow, blood volume, and blood oxygenation often use separate devices and photon populations. Combining these contrasts within a common photon population would enable their direct co-registration while retaining time-of-flight-based depth discrimination. We introduce dual-wavelength time-of-flight interferometric speckle-contrast optical spectroscopy (TOF-iSCOS), built on an interferometric near-infrared spectroscopy (iNIRS) architecture that temporally multiplexes 780 and 852 nm swept lasers through a shared detection channel. It recovers co-registered flow-sensitive field dynamics and wavelength-resolved attenuation from the same complex-field acquisition. Three 50 ps TOF gates sample increasingly late-arriving photons. Within each gate, g_1 was calculated directly as the normalized temporal autocorrelation of the reconstructed complex field. {kappa}2 was reconstructed by finite-time integration of measured g_1 and finite-integration fits yielded decorrelation rates. No camera speckle-variance contrast or Siegert substitution was used. Gate-integrated TPSF intensities yielded optical-density changes {delta}OD, and division by the baseline-TPSF-weighted mean photon path length gave effective {delta}_a for two-wavelength hemoglobin inversion. In 12 forearm cuff-occlusion recordings from 11 adults, TOF-iSCOS detected flow suppression during occlusion and reactive hyperemia after release at both wavelengths. At 780 nm, the Late-minus-Early reactive-hyperemia amplitude in the relative blood-flow index (rBFI) was +0.647 (95% CI 0.194 to 1.124), whereas the Early-minus-Late cuff {delta}_a contrast was +0.196 cm^{-1} (95% CI 0.123 to 0.280). In the photon-limited 852 nm Late gate, the accepted-frame fraction was 0.994 for {kappa}^2-based fitting versus 0.831 for g_1-based fitting. Exploratory phase-resolved analysis suggested that the initial hemoglobin response was concentrated in early-arriving photons, while later responses differed in magnitude and direction. Wavelength, field dynamics, and photon time-of-flight thus provide complementary physiological information; the largest response need not identify the phase of interest.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Characterization of a fiber-coupled SPAD camera system for deep-tissue blood-flow measurement using diffuse correlation spectroscopy 95%
- Multi-plane Imaging of Neural Activity From the Mammalian Brain Using a Fast-switching Liquid Crystal Spatial Light Modulator 94%
- Easy Two-Photon Image Scanning Microscopy with SPAD Array and Blind Image Reconstruction 93%
Similar papers in this journal
- Characterization of red fluorescent reporters for dual-color in vivo three-photon microscopy 93%
- Multimodal retinal imaging by visible light optical coherence tomography and phosphorescence lifetime ophthalmoscopy in the mouse eye 93%
- Implantable photonic neural probes for light-sheet fluorescence brain imaging 92%
Similar papers in this journal
- Wide and Deep Imaging of Neuronal Activities by a Wearable NeuroImager Reveals Premotor Activity in the Whole Motor Cortex 93%
- Kidney Tissue Characterization using Normalized Raman Imaging and Segment-Anything 93%
- Miniaturized microscope for non-invasive imaging of leukocyte-endothelial interactions in human microcirculation 93%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.