Pupil symmetry and Swinging Light Test Performed with VR Headset for Detection of Anisocoria and Relative Afferent Pupillary Defect
Strumbelj, M.; Vidovic Valentincic, N.; Fakin, A.
Show abstract
Purpose: Pupil examination is a routine examination of patients presenting with ophthalmological or neurological symptoms. Our purpose was to determine the sensitivity of pupillometry using HP Reverb G2 Omnicept virtual reality (VR) headset for detecting anisocoria and relative afferent pupillary defect (RAPD). Methods: Twenty-nine patients were included; Group I with asymmetric optic neuropathy (N=21) and Group II with suspected pathological anisocoria (N=8); alongside 19 controls. VR pupillometry consisted of Pupil symmetry test and Swinging light test. Pathological thresholds were established using upper limits of controls. Results were compared with routine pupil exam. Correlations with functional ophthalmological test results were analyzed. Results: RAPD was detected in 16/21 Group 1 patients using both VR pupillometry and standard exam. Remaining 5 had relative afferent pupillary asymmetry (RAPA) within the control range (0.1-0.2 mm). Significant correlation was found between RAPA/RAPD and inter-eye difference in visual acuity and visual field defect (MD) (R=0.58 and 0.68, p<0.01). All patients with >5,8 dB inter-eye MD difference had RAPD. In Group II, pathological anisocoria (>0.8 mm) was detected using VR pupillometry and 1/8 on standard exam. Qualitative differences in pupillary constriction were observed. In control group anisocoria (0.4-0.8 mm) was detected in 37% (7/19); in all greater in the dark (mean 0.2 mm). Conclusion: In comparison to conventional exam VR pupillometry matched detection rate of RAPD and surpassed detection rate of pathological anisocoria. Longitudinal data on pupillary constriction characteristics could significantly contribute to patient diagnosis and monitoring in clinical studies as well as understanding physiological variability.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A Normative Database of A-Scan Data Using the Heidelberg Spectralis Spectral Domain Optical Coherence Tomography Machine 96%
- Hemodynamic Instability and Retinal Vein Occlusion in Glaucoma: Comparative Analysis of Heart Rate Variability and Choroidal Perfusion 95%
- Automated 360-degree goniophotography with the NIDEK Gonioscope GS-1 for glaucoma 95%
Similar papers in this journal
- Visual field evaluation using Zippy Adaptive Threshold Algorithm (ZATA) Standard and ZATA Fast in patients with glaucoma and healthy individuals 95%
- Advanced Retinal Imaging and Ocular Parameters of the Rhesus Macaque Eye 94%
- Two-Photon Microperimetry: A media opacity-independent retinal function assay 94%
Similar papers in this journal
- Automated vision screening of children using a mobile graphic device 95%
- An Open-Source Dataset Of Anti-Vegf Therapy In Diabetic Macular Oedema Patients Over Four Years & Their Visual Outcomes 92%
- Evaluation of OCT biomarker changes in treatment-naive neovascular AMD using a deep semantic segmentation algorithm 92%
Similar papers in this journal
Similar papers in this journal
- Validation of the patient reported outcome measures tool “Catquest” in Odia language 95%
- Clinicopathological Evaluation of Dry eyes and Ocular surface in Newly diagnosed patients of Hyperthyroidism and Hypothyroidism and its Comparison to Healthy Subjects 95%
- Comparison of Efficacy of Dexamethasone and Methylprednisolone in Improving the Partial Pressure of Arterial Oxygen and Fraction of Inspired Oxygen Ratio among COVID-19 Patients 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.