Optimizing Aqueous Humor Liquid Biopsy: Safety and Performance of a Short, Low-Dead-Space Ophthalmic Needle for Anterior Chamber Paracentesis
Singh, A. M.; Yeh, T.-C.; DeBoer, C.; Al-Moujahed, A.; Lin, J. B.; Smith, S. J.; Sanislo, S.; Janjua, K. A.; Lin, T.-C.; Almeida, D. R. P.; Mruthyunjaya, P.; Mahajan, V. B.
Show abstract
Purpose: To evaluate the safety, procedural performance, sample recovery, and surgeon preference of an ophthalmic needle designed specifically for anterior chamber (AC) paracentesis. Methods: In this multicenter study, AC paracentesis was performed in clinic and operating-room settings using a 32-gauge x 4-mm needle with low dead space. The procedure was evaluated using a standardized physician survey. Prespecified outcomes included procedure-related adverse events (primary outcome), needle entry and handling, aspiration and sample recovery, comparative performance versus a 30-gauge needle, and physician preference for future use. Results: A total of 110 needle uses by eight surgeons were included. No ocular complications occurred, including lens or iris injury, hyphema, AC collapse, wound leak, hypotony, infection, or retinal complication, and no procedure required needle exchange or conversion to another device. Two technical events without ocular sequelae were noted, in which needle entry was partial thickness and did not reach the AC (1.8%; exact 95% CI, 0.2%-6.4%). Physicians rated needle entry, handling and sample recovery as good or excellent. Compared with a 30-gauge needle, the study needle was rated as at least comparable across all assessed domains. All surgeons rated it better or much better for intra-procedural safety and preferred it for future AC taps. Conclusions and Relevance: This short, 32-gauge low-dead-space ophthalmic needle demonstrated a favorable safety profile and was preferred over a 30-gauge needle by all surgeons. As aqueous humor liquid biopsy expands in clinical diagnostics and trials, an ophthalmic-specific needle design may help improve the consistency and safety of aqueous humor collection for molecular analysis and broader clinical use. Keywords: Anterior chamber paracentesis; Aqueous humor; Liquid biopsy; Low dead space; Ophthalmic needle
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Using electronic health record data to determine the safety of aqueous humor liquid biopsies for molecular analyses 96%
- Peripheral optical coherence tomography assisted by scleral depression in retinopathy of prematurity 92%
- Zero warm ischemia time in whole-eye transplantation through retrograde extracorporeal perfusion 91%
Similar papers in this journal
- The learning curve of murine subretinal injection among clinically trained ophthalmic surgeons 95%
- Low-cost, Smartphone-based Specular Imaging and Automated Analysis of the Corneal Endothelium 92%
- A Tear-Based Approach for Rapid Identification of Bacterial Pathogens in Corneal Ulcers Using Nanopore Sequencing 91%
Similar papers in this journal
- Automated 360-degree goniophotography with the NIDEK Gonioscope GS-1 for glaucoma 93%
- Sociodemographic predictors of acute corneal hydrops in patients with unstable keratoconus 92%
- The evaluation of a web‐based tool for measuring the uncorrected visual acuity and refractive error in keratoconus eyes: a prospective open‐label method comparison study 92%
Similar papers in this journal
Similar papers in this journal
- Automated Expert-level Scleral Spur Detection and Quantitative Biometric Analysis on the ANTERION Anterior Segment OCT System 93%
- Risk Model for Intraoperative Complication during Cataract Surgery Based on Data from 900,000 Eyes – Previous Intravitreal Injection is a Risk Factor 92%
- Optic nerve tortuosity and displacements during horizontal eye movements in healthy and highly myopic subjects 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.