Testing the reliability of novel Voxel Placement approaches for Magnetic Resonance Spectroscopy
Chhabra, H.; Hehl, M.; Cuypers, K.; Dydak, U.; Nitsche, M. A.; Genc, E.; Burke, M.
Show abstract
BackgroundSingle-voxel magnetic resonance spectroscopy (MRS) is a non-invasive method for measuring clinically and cognitively relevant metabolites. Reliable measurements require precise voxel placement across sessions and participants. We developed a scanner-console-based approach to improve voxel placement precision. MethodsIn a crossover design (n=7; six sessions each), we compared test-retest reliability of three voxel placement methods in a reference benchmark (left parietal cortex) and a technically challenging region (left ventromedial prefrontal cortex). Methods included (1) conventional anatomy-based placement, (2) mask-guided real-time positioning (MGRP), and (3) semiautomated session-locked voxel repositioning (SSVR). Resting-state MRS data were acquired using PRESS and MEGA-PRESS. Within-subject reliability of voxel placement and metabolite concentrations, namely, total N-acetylaspartate (tNAA), total Creatine (tCr), GABA (gamma-aminobutyric acid), and Glx (glutamate + glutamine) are reported using the coefficient of variation (CV), the intraclass correlation coefficient (ICC), minimal detectable change (MDC), and the spatial overlap. ResultsSSVR markedly improved voxel placement reliability, increasing spatial overlap (up to 88%) and achieving near-perfect geometric reproducibility (ICC = 0.99) compared to conventional anatomy-based placement and MGRP. SSVR improved tissue composition consistency and reduced metabolite variability in the technically challenging region (variability reduction of [~]70% tCr, [~]59% tNAA, and [~]51% Glx) while further refining already stable measurements in the benchmark region (tNAA from [~]15% to [~]10%). ConclusionBoth MGRP and SSVR improved voxel placement and metabolite measurement reproducibility compared with conventional anatomy-based placement. SSVR further enhanced within-subject reproducibility across repeated sessions, particularly in the technically challenging region, providing a robust approach for longitudinal single-voxel MRS studies.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Quantitative T1-relaxation corrected metabolite mapping of 12 metabolites in the human brain at 9.4 T 95%
- Deuterium metabolic imaging and hyperpolarized 13 C-MRI of the normal human brain at clinical field strength reveals differential cerebral metabolism 95%
- Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct ( 2 H) and indirect ( 1 H) detection of deuterium labeled compounds at 7T and clinical 3T 95%
Similar papers in this journal
Similar papers in this journal
- Noise decorrelation optimizes SNR of GABA-edited MRS data: A comparison of RF coil combination methods 95%
- Advancing High-Resolution 7T Diffusion MRI: Evaluating Phase-Encoding Correction Strategies for Distortion Correction from Basic to Four-Way Acquisitions 94%
- Increased Brain Volumetric Measurement Precision from Multi-Site 3D T1-weighted 3T Magnetic Resonance Imaging by Correcting Geometric Distortions 94%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.