Pro-arrhythmogenicity of single-tip vs. multi-spline catheters in post-MI VT ablation: a prospective, international, two-center experience

Rademaker, R.; De Smet, M. A. J.; Jensen, T.; de Riva Silva, M.; Lukac, P.; Zeppenfeld, K.

2026-08-10 cardiovascular medicine
10.64898/2026.08.06.26359917 medRxiv
Show abstract

Background Substrate mapping using multielectrode catheters is increasingly used for post-myocardial infarction (MI) ventricular tachycardia (VT) avoiding repeated VT induction and mapping during VT. However, these catheters may mechanically induce ventricular arrhythmias with hemodynamic compromise. This study compares pro-arrhythmogenicity between single-tip and multi-spline catheters during functional substrate mapping. Methods Thirty post-MI patients (age 68{+/-}8 years, 97% male, LVEF 40% [IQR 33-46]) referred for VT ablation at two centers (2021-2024) underwent endocardial mapping during baseline rhythm in random order with both a multi-spline catheter (Octaray, n=4; Pentaray, n=26) and a single-tip QDOT catheter. The protocol was prematurely terminated if (i) two mechanically induced VTs required ECV, (ii) recurrent ATP-treated mechanical VTs caused hemodynamic compromise, or (iii) excessive mechanically induced ectopy impaired catheter contact. Mapping time, point density, and mechanically induced arrhythmias were assessed. Results Multi-spline catheters enabled faster mapping (26{+/-}9 vs 60{+/-}16 minutes, p<0.001) with more acquired points (p<0.001). VTs were more frequently mechanically induced with multi-spline catheters (median 2 [IQR 1-4] vs 0 [0-3], p<0.05) and these VTs were faster (304ms, IQR 292-320] vs 373ms, IQR [316-405], p=0.01) and degenerated more often into VF (3 vs. 0). Overall, 17 patients (57%) experienced at least one mechanically induced VT; seven (23%) required cardioversion, and mapping was prematurely terminated in eight (27%), all while using multi-spline catheters. Conclusion Multi-spline catheters allow rapid substrate mapping but with substantial risk of mechanically induced arrhythmias, requiring premature termination of substrate mapping because of safety concerns. Their use in post-MI VT ablation warrants careful risk?benefit assessment.

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.