Single-shot simultaneous BOLD and velocity-encoding MRI for functional and slow-flow imaging
Widmaier, M. S.; Chao, T.-H.; Emir, U.; Chang, W.-T.
Show abstract
Cerebrospinal fluid (CSF) motion is coupled with global blood oxygenation level-dependent (BOLD) fluctuations, but the spatial relationship between regional brain activity and CSF dynamics remains poorly understood. Here, we developed a single-shot BOLD-VENC sequence that combines gradient-echo BOLD imaging with spin-echo velocity encoding following the same RF excitation, enabling simultaneous measurement of brain-wide BOLD activity and spatially resolved slow CSF velocity at 3T. The velocity measurement was validated in a slow-flow phantom and in five healthy participants using paced-breathing, breath-holding, and visual-stimulation experiments. Phantom measurements showed strong agreement with prescribed velocities over 0.1-1.0 mm/s (R2 = 0.93-0.98). In vivo measurements demonstrated respiratory- and cardiac-dependent changes in CSF velocity magnitude and direction across the ventricles and cortical subarachnoid spaces (SAS). The established coupling between the negative derivative of the global BOLD signal and fourth-ventricle CSF inflow was reproduced, with a peak lag of 0.9 s. Global BOLD fluctuations were also coupled with spatially distributed CSF velocity changes across ventricular and cortical CSF spaces, with a similar peak lag of 1.2 s. During visual checkerboard stimulation, BOLD-CSF velocity coupling was localized primarily to the SAS surrounding the activated visual cortex, demonstrating a regional relationship between local BOLD activity and nearby CSF motion. These findings establish the feasibility of simultaneous BOLD and slow CSF velocity imaging and extend BOLD-CSF coupling from a global measure toward spatially resolved assessment of hemodynamic-CSF interactions.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Single-shot Echo Planar Time-resolved Imaging for multi-echo functional MRI and distortion-free diffusion imaging 96%
- Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging 95%
- Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T 95%
Similar papers in this journal
- Framewise multi-echo distortion correction for superior functional MRI 95%
- Visual stimulus-evoked blood velocity responses in individual human posterior cerebral arteries measured with dynamic phase-contrast functional MR angiography 95%
- Modeling dynamic inflow effects in fMRI to quantify cerebrospinal fluid flow 95%
Similar papers in this journal
- The dot-compartment revealed? Diffusion MRI with ultra-strong gradients and spherical tensor encoding in the living human brain 96%
- 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI 95%
- Cerebrospinal Fluid Flow within Ventricles and Subarachnoid Space Evaluated by Velocity Selective Spin Labeling MRI 95%
Similar papers in this journal
- Temporal signal-to-noise changes in combined multiband- and slice-accelerated echo-planar imaging with a 20- and 64-channel coil 96%
- Non-Invasive Perfusion MR Imaging of the Human Brain via Breath-Holding 96%
- An in-vivo study of BOLD laminar responses as a function of echo time and static magnetic field strength 95%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.