E-HAPLOS: Electrical Impedance Human-guided Assesment with Pressure for Lump Observation System
Posio, R. J. E.; Magpili, K. G.
Show abstract
Breast cancer is the leading cause of cancer-related deaths among women in the Philippines. Over 65% of these cases are diagnosed when they are advanced (Montemayor, 2023). This highlights the need for improved early screening devices. E-HAPLOS, or Electrical Impedance Human-guided Assessment with Pressure for Lump Observation System, is a low-cost glove with sensors designed to improve early detection of suspicious breast lump through touch. It integrates force-sensitive resistors (FSRs) to measure tissue stiffness and Electrical Impedance Spectroscopy (EIS) to analyze conductivity across different frequencies--properties that are closely linked to breast cancer. The prototype uses an ESP32 microcontroller that transmits real-time pressure and impedance data to the website. Tested on gelatin breast models with simulated lump, the FSRs effectively identified lump locations by recording higher mean force values (45.81 kPa vs. 33.57 kPa). This guided approach allowed the combined FSR-EIS system to reach a diagnostic performance with an Area Under the Curve (AUC) above 0.94, a significant improvement over unguided measurement (AUC {approx} 0.78). A two-way ANOVA confirmed a significant difference in diagnostic performance based on the system modality (p < 0.001). Tukeys Honesty Significant Difference (HSD) test showed that the FSR-EIS system was statistically superior to both the unguided EIS (p < 0.001) and FSR-only system (p = 0.041). Results demonstrate the synergistic effect of the integrated system, enabling accurate differentiation of suspicious lumps from normal tissue. The FSR-EIS system of the E-HAPLOS glove shows a great potential for detection of lumps in simulated breasts as a screening tool.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Comparison of TENS electrodes and textile electrodes for electrocutaneous warning 93%
- Variability of Tissue Mechanical Response in Sus Domesticus Porcine Models from in vivo to ex vivo Conditions 92%
- Impact of galvanic vestibular stimulation electrode current density on brain current flow patterns: Does electrode size matter? 92%
Similar papers in this journal
- Commercially-available heart rate monitor repurposed into a 9-gram standalone device for automatic arrhythmia detection with snapshot electrocardiographic capability: a pilot validation 91%
- Passive Microwave Radiometry (MWR) for diagnostics of COVID-19 lung complications in Kyrgyzstan 90%
- A Machine Learning Ensemble Based on Radiomics to Predict BI-RADS Category and Reduce the Biopsy Rate of Ultrasound-Detected Suspicious Breast Masses 89%
Similar papers in this journal
- Digitizing ECG image: new fully automated method and open-source software code 92%
- An algorithm to detect dicrotic notch in arterial blood pressure and photoplethysmography waveforms using the iterative envelope mean method 89%
- Automated IntraVascular UltraSound Image Processing and Quantification of Coronary Artery Anomalies: The AIVUS-CAA software 89%
Similar papers in this journal
Similar papers in this journal
- Fusion of Fully Integrated Analog Machine Learning Classifier with Electronic Medical Records for Real-time Prediction of Sepsis Onset 92%
- Effects of Electrocardiograms QRS Detection Algorithms in Heart Rate Variability Metrics 91%
- EEG-based diagnostics of the auditory system using cochlear implant electrodes as sensors 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.