Analytical Performance and 99th Percentile Upper Reference Limit of the Novel SPINCHIP High-Sensitivity Cardiac Troponin I Point-of-Care Assay
MacKenzie, J.; Aakre, K. M.; Paus, D.; Broughton, M. N.; Storvold, G. L.; Olberg, A.; Stenmark, S.; Booij, B. B.; Scott, S.; Michel-Busseret, S.; Octave, L.; Tveit, A.; Lyngbakken, M. N.; Nilsson, J.; Rosjo, H.
Show abstract
BACKGROUND In line with International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) recommendations for high-sensitivity cardiac troponin assays, analytical validation and reference limit assessments are required to confirm that an assay meets performance criteria. This study evaluated the analytical performance and established the 99th percentile upper reference limit (URL) for the SPINCHIP High-Sensitivity Cardiac Troponin I (SPINCHIP hs-cTnI) point-of-care assay. METHODS Analytical performance characteristics, including the limit of blank (LoB), limit of detection (LoD), and limit of quantification (LoQ), were assessed. Additionally, 1,053 plasma samples and 1,055 whole-blood samples were used to determine the URL. Imprecision around the 99th percentile URL was evaluated as part of the analytical validation. High-sensitivity criteria were assessed by confirming measurable cTnI in [≥]50% of healthy individuals (n=432 plasma; n=431 whole blood) and achieving imprecision <10% at the 99th percentile (plasma, n=960; whole blood, n=480). RESULTS SPINCHIP hs-cTnI demonstrated a LoB of 0.3 ng/L; LoDs of 0.8 ng/L (plasma) and 0.9 ng/L (whole blood); and LoQs of 1.1 ng/L (plasma) and 1.4 ng/L (whole blood). The analytical measuring range was 1.1-9,000 ng/L. Imprecision at the common 99th percentile URL (14 ng/L) was 5.8%; for men (URL=16 ng/L) 5.6% and for women (URL=10 ng/L) 6.3%. Greater than 85.2% (94.0% and 76.1% in men and women, respectively) of healthy individuals showed measurable cTnI above the LoD. CONCLUSIONS The SPINCHIP hs-cTnI assay meets the IFCC high-sensitivity requirements, demonstrating <10% imprecision at the 99th percentile, reliable low-concentration precision and cTnI detection in more than half of healthy individuals.
Matching journals
The top 11 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Validating quantitative PCR assays for cell-free DNA detection without DNA extraction: Exercise induced kinetics in systemic lupus erythematosus patients 95%
- Analytical and clinical validation of step counting method in people living with amyotrophic lateral sclerosis 92%
- Small-molecule metabolome identifies potential therapeutic targets against COVID-19 92%
Similar papers in this journal
- A High-throughput Microsphere-based Immunoassay of Anti-SARS-CoV-2 IgM Testing for COVID-19 Diagnostics 93%
- Analytical performance of 17 commercially available point-of-care tests for CRP to support patient management at lower levels of the health system 92%
- Performance of serum apolipoprotein-A1 as a sentinel of Covid-19 92%
Similar papers in this journal
- Development, validation and application of an LC-MS/MS method quantifying free forms of the micronutrients queuine and queuosine in human plasma using a surrogate matrix approach 95%
- REverse transcriptase ACTivity (REACT) assay for point-of-care measurement of established and emerging antiretrovirals for HIV treatment and prevention 92%
- A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.