Back

Accuracy of a Smart-Ring VO2max Estimate and Five Published Prediction Equations Against Cardiopulmonary Exercise Testing: Development and Validation Study With Population-Scale Analysis

Dhawale, N.; Mukundan, S.; Agarwal, A.; Mondal, D.; Shanmugam, A.; Kumar, P.; Mittal, M.; Narasimhan, V.

2026-07-17 sports medicine
10.64898/2026.07.16.26358226 medRxiv
Show abstract

Background. Maximal oxygen uptake (VO2max) is a leading marker of cardiorespiratory fitness and a strong predictor of all-cause mortality. Cardiopulmonary exercise testing (CPET) is the reference method but is resource-intensive, so consumer wearables estimate VO2max from passively collected signals; these estimates compress the fitness range, returning near-correct group averages while ranking individuals poorly. No peer-reviewed validation of a smart-ring VO2max estimate against CPET has been reported, and none in a South Asian cohort. Objective. To validate the Ultrahuman Ring AIR VO2max estimate against laboratory CPET, benchmark it against published prediction equations, and assess its generalization and construct validity. Methods. In a single-site paired ring-CPET cohort (N = 101; mean CPET peak VO2 43.3 mL{middle dot}kg-{superscript 1}{middle dot}min-{superscript 1}, SD 9.9), peak oxygen uptake was measured by treadmill or cycle-ergometer CPET, and the Ultrahuman Ring AIR estimate was computed from passively collected signals using a transparent ensemble based on published equations. Ensemble weights and calibration were selected on an 85-subject development set by an automated search minimizing a composite 5-fold cross-validated error criterion; the locked estimate was evaluated on a 16-subject held-out test set. The calibrated coefficients are proprietary. Agreement was quantified with mean absolute error (MAE), bias, Pearson r, regression slope and Lin's concordance correlation coefficient (CCC; bootstrap 95% CIs), and Bland-Altman limits of agreement. Separately, in 181,133 de-identified Ring users (no CPET reference), construct validity was assessed against ring-measured sleep, continuous glucose monitoring (n = 2,597), and a venous blood panel (n up to 15,203), adjusted for age, sex, and BMI, with lipoprotein(a) as a pre-specified negative control. Reporting followed TRIPOD and STARD. Results. With a self-reported fitness level provided, the estimate agreed with CPET peak VO2 at MAE 4.68 mL{middle dot}kg-{superscript 1}{middle dot}min-{superscript 1} (95% CI 3.93 to 5.49), Pearson r 0.79, CCC 0.79, and slope 0.71. The five published equations were worse on every metric (MAE 6.2 to 10.6, CCC 0.28 to 0.56, slope 0.32 to 0.42), each compressing the fitness range. On the held-out test set (n = 16), agreement held (r 0.84, slope 0.81, MAE essentially unchanged). Without the fitness input, full-cohort MAE was 5.16, still ahead of every published equation. At population scale, higher estimated fitness tracked a healthier profile on measurements the estimate does not use: better ring-measured sleep; higher continuous-glucose time in target range (79.6% versus 61.5%, top versus bottom decile; n = 222 and 399 of 2,597 users); and lower triglycerides, fasting glucose, and HOMA-IR (n up to 15,203 assayed per marker). These associations held after adjustment for age, sex, and BMI, whereas the pre-specified negative control lipoprotein(a) did not separate the deciles. Conclusions. The Ultrahuman Ring AIR VO2max estimate agreed with laboratory CPET substantially better than published prediction equations, held its agreement on held-out subjects, and ordered a large population along independent cardiometabolic gradients consistent with true fitness.

Matching journals

The top 9 journals account for 50% of the predicted probability mass.

1
JAMA Network Open
130 papers in training set
Top 0.2%
9.7%
2
PLOS ONE
5266 papers in training set
Top 22%
7.9%
3
Nature Communications
5641 papers in training set
Top 27%
5.5%
4
Scientific Reports
3612 papers in training set
Top 16%
5.5%
5
Communications Biology
993 papers in training set
Top 1%
5.5%
6
npj Digital Medicine
118 papers in training set
Top 1%
4.9%
7
PLOS Digital Health
106 papers in training set
Top 1%
4.3%
8
Medicine & Science in Sports & Exercise
16 papers in training set
Top 0.1%
4.3%
9
International Journal of Obesity
29 papers in training set
Top 0.2%
3.2%
50% of probability mass above
10
International Journal of Behavioral Nutrition and Physical Activity
15 papers in training set
Top 0.1%
3.2%
11
Journal of Applied Physiology
32 papers in training set
Top 0.2%
3.2%
12
Experimental Gerontology
12 papers in training set
Top 0.1%
2.7%
13
Communications Medicine
113 papers in training set
Top 1%
2.5%
14
eBioMedicine
183 papers in training set
Top 2%
2.4%
15
Sleep Medicine
19 papers in training set
Top 0.2%
2.4%
16
Journal of the American Heart Association
140 papers in training set
Top 3%
1.9%
17
Frontiers in Physiology
106 papers in training set
Top 1%
1.7%
18
International Journal of Environmental Research and Public Health
128 papers in training set
Top 4%
1.4%
19
eClinicalMedicine
77 papers in training set
Top 1%
1.3%
20
JMIR mHealth and uHealth
11 papers in training set
Top 0.2%
1.3%
21
Nutrients
67 papers in training set
Top 1%
1.1%
22
Aging Cell
165 papers in training set
Top 2%
1.1%
23
BMJ Open
601 papers in training set
Top 11%
1.1%
24
Frontiers in Cardiovascular Medicine
53 papers in training set
Top 2%
1.1%
25
European Heart Journal - Digital Health
18 papers in training set
Top 0.9%
1.0%
26
European Journal of Applied Physiology
14 papers in training set
Top 0.2%
1.0%
27
Frontiers in Neuroscience
256 papers in training set
Top 6%
0.9%
28
Journal of the American Geriatrics Society
12 papers in training set
Top 0.2%
0.8%
29
BMC Cardiovascular Disorders
18 papers in training set
Top 1%
0.8%
30
Journal of Medical Internet Research
87 papers in training set
Top 3%
0.6%