Back

Drug-Coated Devices, Wound Healing, and Mortality After Endovascular Therapy for Chronic Limb-Threatening Ischemia

Lee, Y.; Rodway, A. D.; Maytham, G. D.; Ntagiantas, N.; Walton, I.; Pazos-Casal, F.; Allan, C.; Brodmann, M.; Schlager, O.; Harris, J.; Heiss, C.

2026-07-17 cardiovascular medicine
10.64898/2026.07.14.26358110 medRxiv
Show abstract

Background: The clinical benefit and safety of drug-coated devices in chronic limb-threatening ischemia remain debated, particularly after recent randomized evidence questioning paclitaxel-coated technologies. We evaluated wound healing, limb outcomes, and mortality after infrainguinal endovascular therapy with uncoated, paclitaxel-coated, and sirolimus-coated devices. Methods: Consecutive patients with chronic limb-threatening ischemia undergoing successful infrainguinal endovascular therapy in a prospective single-center service evaluation were analyzed. The primary exposure was use of any drug-coated device during the index procedure. Inverse probability of treatment weighting and multivariable Cox models were used to adjust for baseline differences. Exploratory analyses compared paclitaxel-coated, sirolimus-coated, and uncoated devices. Results: Among 341 patients, 244 (71.6%) received at least one drug-coated device. After weighting, drug-coated device use was associated with more frequent wound healing, whereas major amputation, clinically driven target lesion revascularization, major adverse limb events, and death did not differ significantly between groups. In weighted multivariable models, drug-coated device use remained associated with wound healing (HR, 1.86; 95% CI, 1.14?3.02), but not with mortality or major limb events. Exploratory drug-specific analyses suggested the highest wound-healing rates among patients treated with sirolimus-coated devices, while mortality was comparable between paclitaxel-coated and uncoated devices. Conclusion: In this real-world cohort of patients with chronic limb-threatening ischemia undergoing infrainguinal endovascular therapy, drug-coated device use was not associated with increased adjusted 1-year mortality and was associated with improved wound healing. Exploratory analyses suggested favourable wound-healing outcomes with sirolimus-coated balloons, with a lower observed mortality signal that warrants confirmation in larger comparative studies.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

1
Journal of the American Heart Association
140 papers in training set
Top 0.1%
30.4%
2
Circulation
74 papers in training set
Top 0.4%
6.6%
3
PLOS ONE
5266 papers in training set
Top 29%
5.4%
4
Stroke: Vascular and Interventional Neurology
14 papers in training set
Top 0.2%
4.7%
5
The American Journal of Cardiology
17 papers in training set
Top 0.4%
4.7%
50% of probability mass above
6
Journal of the American College of Cardiology
12 papers in training set
Top 0.1%
4.0%
7
Frontiers in Cardiovascular Medicine
53 papers in training set
Top 1.0%
3.2%
8
Scientific Reports
3612 papers in training set
Top 44%
2.4%
9
International Journal of Cardiology
14 papers in training set
Top 0.4%
2.4%
10
Annals of Biomedical Engineering
37 papers in training set
Top 0.4%
2.3%
11
Stroke
40 papers in training set
Top 0.5%
2.1%
12
Heart
11 papers in training set
Top 0.5%
2.1%
13
Journal of Thrombosis and Haemostasis
32 papers in training set
Top 0.2%
1.9%
14
Nature Communications
5641 papers in training set
Top 46%
1.7%
15
Open Heart
21 papers in training set
Top 0.7%
1.7%
16
Cardiovascular Research
37 papers in training set
Top 0.9%
1.1%
17
Brain and Behavior
43 papers in training set
Top 1%
1.1%
18
Arteriosclerosis, Thrombosis, and Vascular Biology
71 papers in training set
Top 1%
1.1%
19
BMJ Open
601 papers in training set
Top 12%
1.0%
20
Journal of Clinical Medicine
97 papers in training set
Top 4%
1.0%
21
European Heart Journal
22 papers in training set
Top 1%
1.0%
22
eLife
5828 papers in training set
Top 66%
0.8%
23
PLOS Medicine
110 papers in training set
Top 3%
0.8%
24
Advanced Healthcare Materials
85 papers in training set
Top 2%
0.6%