Data-driven calibration of low-cost wearable motion trackers for gait and dynamic stability measurement

He, Y.; Dong, Y.; Brodie, M. A.; Kim, J.; Lord, S. R.; Okubo, Y.

2026-07-15 sports medicine
10.64898/2026.07.13.26357919 medRxiv
Show abstract

Low cost inside out wearable trackers can be deployed at scale to measure body motion, but errors in estimated sensor position propagate through coordinate transformations into derived gait and dynamic-stability metrics. Healthy adults walked on a treadmill at 0.5 to 2.0 m/s while VIVE Ultimate Tracker (VUT) and Vicon data were recorded. Data-driven calibration models were developed to correct tracker coordinates and to estimate full body centre of mass (CoM) from a sacrum-only configuration. Agreement with Vicon was assessed using RMSE, mixed-effects Bland-Altman limits of agreement, MAE, and intraclass correlation coefficients. Calibration improved coordinate-level agreement. For gait parameters, model-corrected VUT showed small errors against Vicon (MAE: 0.24 to 0.71 mm step height, 1.73 to 4.63 mm step length, 0.15 to 0.95 mm step width, 0.26 to 0.88 mm foot clearance). Proxy CoM-derived margin of stability (MoS) agreed excellently with Vicon. For the sacrum-only pipeline, calibration reduced CoM RMSE from 103.65 to 104.04 mm to 7.55 to 8.95 mm, and markedly reduced systematic error in stability outcomes, with extrapolated CoM bias decreasing from 172.92 to 0.29 mm and MoS bias from -75.09 to -3.54 mm. Data-driven calibration improved the measurement utility of low-cost VUTs, enabling inexpensive, relatively simple gait and stability measurement from a sacrum-only setup in controlled settings.

Matching journals

The top 1 journal accounts for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.