Persistent Iatrogenic Atrial Septal Defect Following Pulsed Field Ablation Guided by Left Atrial Intracardiac Echocardiography: Incidence, Predictors, and Clinical Outcomes.
Mraiyan, M.; Nair, G.; Doty, B.; Nair, D. G.
Show abstract
Background: Iatrogenic atrial septal defect (iASD) is a known consequence of transseptal catheterization. Left atrial intracardiac echocardiography (LA ICE) requires additional septal instrumentation, yet data on persistent iASD after pulsed field ablation (PFA) with an LA ICE workflow remain limited. We evaluated the incidence, predictors, and one-year clinical significance of persistent iASD in this setting. Methods: Consecutive patients undergoing PFA for atrial fibrillation with LA ICE were prospectively evaluated with transthoracic echocardiography before ablation and at one year, including systematic agitated saline contrast. Persistent iASD was defined as residual interatrial shunting on color Doppler at follow-up, classified as small (<3 mm), moderate (3-5 mm), or large (>5 mm). Groups were compared by t-test and chi-square test. Results: Among 850 patients, persistent iASD was identified in 153 (18.0%) at one year; 97 (63.4%) were small and 56 (36.6%) moderate, with no large defects. All shunts were left-to-right. No stroke or transient ischemic attack, paradoxical embolism, hypoxemia, right-heart enlargement, or septal closure occurred. Persistent iASD was associated with female sex (64.7% vs 48.1%), longer septal dwell time (52{+/-}12 vs 31{+/-}11 min), higher left atrial pressure (28{+/-}4 vs 12{+/-}3 mmHg), lower LVEF (32{+/-}11% vs 54{+/-}14%), and larger-caliber sheaths ([≥]17 Fr; 80.4% vs 48.2%; all p<0.001). Conclusions: Persistent iASD following PFA with LA ICE occurs in approximately one in five patients but is predominantly small, exclusively left-to-right, and clinically benign at one year. Persistence is associated with mechanical and hemodynamic factors, particularly sheath caliber, rather than the ablation energy source.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Multicenter analysis of atrioesophageal fistula rates before and after adoption of active esophageal cooling during atrial fibrillation ablation 96%
- Enhancing Ventricular Tachycardia Ablation Outcomes: The Impact Of Functional Mapping In Chagas Cardiomyopathy 96%
- Peri-Procedural Intravascular Hemolysis during Atrial Fibrillation Ablation: A Comparison of Pulsed-Field with Radiofrequency Ablation 96%
Similar papers in this journal
- Procedural Volume and Outcomes with Atrial Fibrillation Ablation: A Report from the NCDR AFib Ablation Registry 97%
- Catheter Ablation Approach Targeting Epicardial Connections to the Right Pulmonary Vein Antrum Detected before Pulmonary Vein Isolation 96%
- High Initial Heart Rate Score is an Independent Predictor of New Atrial High-Rate Episodes in Pacemaker Patients with Sinus Node Dysfunction 95%
Similar papers in this journal
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 94%
- Prognostic Value of Patient-Reported Outcomes in Predicting Long-term Mortality after Transcatheter Aortic Valve Replacement (TAVR) 94%
- The Effect of Medical Therapy on Reducing the Risk of Pacing Induced Cardiomyopathy 94%
Similar papers in this journal
- Atrial functional substrates for the prediction of atrial fibrillation recurrence after pulmonary vein isolation 97%
- Prognostic value of compact myocardial thinning in patients with left ventricular non-compaction 94%
- Ticagrelor vs Clopidogrel: the Impact of Platelet Inhibition on Cerebrovascular Microembolic Events during TAVR 94%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.