Intraoral Ultrasound for Detection of Alveolar Bone Changes Following Periodontal Surgery: A Prospective Validity and Precision Study
Pandya, M.; Tran, B.; Amjadian, M.; Alterman, S.; Chang, H.; Min, Y.; Khan, S.; Jokerst, J.; Chen, C.
Show abstract
Background Alveolar bone assessment in periodontal practice relies on radiography and clinical probing, both of which have well-documented limitations in precision. Intraoral high-frequency ultrasonography (US) offers a radiation-free alternative with potential for sub-millimeter resolution, the validity and precision for detecting minute osseous changes have not been established. The purpose of this study was to evaluate the concurrent validity and measurement precision of intraoral US for detecting alveolar bone-level changes in patients undergoing crown lengthening and osseous surgery, thereby enabling its translation to monitor osseous changes in patients with periodontitis. Methods Ten patients (28 tooth sites) undergoing crown lengthening or osseous surgery at a USC Advanced Grad Perio clinic were enrolled in this prospective observational study. Distance from the cementoenamel junction (CEJ) to the Alveolar bone crest (ABC) was measured at pre- and post-operative time points using a 40 MHz handheld intraoral US transducer and, intraoperatively, by standardized clinical photography. Agreement was assessed by Pearson correlation and Bland-Altman analysis. Measurement precision was quantified using the standard error of measurement (SEM) and minimum detectable change (MDC). Results Preoperative agreement between methods was excellent (r = 0.977; Bland-Altman bias = -0.009 mm; 95% limits of agreement [LoA]: +-0.40 mm). Post-operative correlation remained strong (r = 0.912; bias = 0.123 mm; LoA: -0.85 to +1.10 mm). Both methods detected statistically significant post-surgical increases in the ABC-to-CEJ distance (p < 0.001), as anticipated. US demonstrated substantially superior precision: preoperative SEM 0.058 mm with US versus 0.128 mm clinically, yielding MDC values of 0.160 mm (US) versus 0.354 mm (clinical), providing a 2.2-fold precision advantage. Conclusions Intraoral US demonstrated strong concurrent validity with clinical photography and a reproducible precision advantage in detecting alveolar bone-level changes in patients with periodontitis. These findings support its clinical utility as a radiation-free, high-sensitivity bone monitoring tool. Larger longitudinal studies with CBCT validation are warranted.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A novel system for classifying tooth root phenotypes 93%
- Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: an in vitro study 93%
- The petrous bone contains high concentrations of osteocytes: one possible reason why ancient DNA is better preserved in this bone. 92%
Similar papers in this journal
- Trabeculae microstructure parameters serve as effective predictors for marginal bone loss of dental implant in the mandible 94%
- Evaluation of longitudinal time-lapsed in vivo micro-CT for monitoring fracture healing in mouse femur defect models 92%
- Development and Validation of Collaborative Robot-assisted Cutting Method for Iliac Crest Flap Raising: Randomized Crossover Trial 92%
Similar papers in this journal
- Fully automatic segmentation of craniomaxillofacial CT scans for computer-assisted orthognathic surgery planning using the nnU-Net framework 93%
- Pairwise learning of MRI scans using a convolutional Siamese network for prediction of knee pain 86%
- Impact of Non-Contrast Enhanced Imaging Input Sequences on the Generation of Virtual Contrast-Enhanced Breast MRI Scans using Neural Networks 86%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.