Deep-Tissue Hemodynamic Sensing: Comparing Impedance and Photoplethysmography for Wearable Blood Pressure Estimation
Thomson, S.; Jung, S.; Pantelopoulos, A.; Deshpande, A.; Cai, L.; Blanchard, E.; Wasson, J.; Mukherjee, D.; Sunden, L.; Sheng, S.; Patel, S.
Show abstract
The pursuit of continuous, cuffless blood pressure (BP) monitoring is constrained by the superficial sensing depth of photoplethysmography (PPG). Impedance plethysmography (IPG) offers deeper tissue penetration, but its comparative value over PPG remains unquantified at scale. In this comparative study of 261 participants (130 hypertensive, 131 non-hypertensive), we utilized a custom dual-modality wearable prototype to capture simultaneous IPG and PPG signals. Over 150,000 cardiac cycles were analyzed using an unsupervised archetype discovery pipeline to quantify beat-to-beat morphological heterogeneity. IPG resolved up to three distinct morphological modes per participant, whereas co-located PPG converged into highly conserved, uniform profiles. IPG captured specific signatures of pathological arterial remodeling and physiological habitus; ventral forearm IPG pulse amplitude exhibited a significant main effect for BP status (p = 0.024), a relationship absent in the co-located PPG signal. Furthermore, increasing body mass index (BMI) significantly attenuated the prevalence of steep-upstroke archetypes in IPG (p = 0.035), quantifying a likely damping effect of adipose tissue. Deep-tissue bioimpedance captures rich, heterogeneous hemodynamic signatures including arterial-dominant morphologies that are invisible to optical sensors. Transitioning from optical pulse wave analysis to bioimpedance-based models may offer a promising pathway for accurate wearable cardiovascular monitoring.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress 89%
- Enhanced Brain-Heart Connectivity as a Precursor of Reduced State Anxiety After Therapeutic Virtual Reality Immersion 88%
- Reinnervation of Muscle Targets Enhances the Separability of Motor Unit Signals Following Peripheral Nerve Transfers 88%
Similar papers in this journal
- Utility of estimated pulse wave velocity for assessing vascular stiffness: comparison of methods 92%
- I-Spin live: An open-source software based on blind-source separation for real-time decoding of motor unit activity in humans 90%
- TMAO, a seafood-derived molecule, produces diuresis and reduces mortality in heart failure rats 89%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.