Back

Diagnostic Concordance of Immediate Versus 1-Hour Technetium-99m Hydroxydiphosphonate Scintigraphy in Suspected Transthyretin Amyloid Cardiomyopathy

Costa, A.; Suits, A.; Miller, J.; Ferencik, M.; German, D. M.; Shalen, E. F.; Choudhary, G.; Szidonya, L.; Nguyen, M.; Mallak, N.; Obrzut, S.; Masri, A.

2026-06-17 cardiovascular medicine
10.64898/2026.06.16.26355752 medRxiv
Show abstract

Background Bone-avid tracer myocardial scintigraphy for the diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM) has traditionally employed imaging at one or 3-hour intervals. Technetium-99m hydroxydiphosphonate (99mTc-HDP) has unique characteristics that may enable earlier imaging. We investigated the diagnostic concordance of immediate versus 1-hour acquisitions. Methods Consecutive patients with suspected ATTR-CM underwent planar imaging and SPECT/CT immediately and at 1-hour following the administration of 99mTc-HDP. Perugini grades and heart to contralateral lung (H/CL) ratios were assessed. Target-to-background ratios (TBRs) were calculated on the SPECT/CT acquisitions using the left ventricular (LV) septum and three background regions: aorta, LV blood-pool, and vertebrae. We assessed diagnostic concordance using Cohen's Kappa ({kappa}), temporal stability using paired t-tests, and correlation between timepoints using Pearson's coefficient (r). The 1-hour SPECT/CT interpretation served as the protocol reference standard. Results Forty-eight patients (83% male; median age, 80 [73-85] years) were evaluated. One-hour SPECT/CT identified 19 positive and 29 negative cases. Immediate SPECT/CT demonstrated 100% diagnostic concordance with the 1-hour reference standard ({kappa} = 1.000; 95% CI: 1.00 to 1.00; p < 0.001). The LV septum/LV Blood-Pool TBR showed the highest correlation (r = 0.956; 95% CI: 0.922 to 0.975; p < 0.001). The LV Septum/Aorta TBR demonstrated high correlation (r = 0.918; 95% CI: 0.857 to 0.953; p < 0.001) and remained stable in the ATTR-negative cohort (-0.02; 95% CI: -0.08 to 0.04; p = 0.54). Significant decrease in the LV Septum/Vertebrae TBR in the ATTR-negative (-0.55; 95% CI: -0.64 to -0.47; p < 0.001) and ATTR-positive cohorts (-1.14; 95% CI: -1.39 to -0.89; p < 0.001) was observed. Conclusions Immediate 99mTc-HDP SPECT/CT is diagnostically concordant with standard 1-hour protocols. By leveraging SPECT/CT and the favorable kinetics of 99mTc-HDP, immediate-phase imaging can accurately reproduce 1-hour acquisitions in cases of suspected ATTR-CM. This expedited approach may improve nuclear laboratory throughput and patient satisfaction.

Matching journals

The top 9 journals account for 50% of the predicted probability mass.

1
PLOS ONE
5266 papers in training set
Top 14%
13.0%
2
Cureus
68 papers in training set
Top 0.1%
10.2%
3
Scientific Reports
3612 papers in training set
Top 9%
7.0%
4
The American Journal of Cardiology
17 papers in training set
Top 0.4%
5.4%
5
Talanta
14 papers in training set
Top 0.1%
4.2%
6
Diagnostics
50 papers in training set
Top 0.5%
3.4%
7
BMJ Open
601 papers in training set
Top 6%
3.4%
8
Biomedicines
67 papers in training set
Top 0.3%
3.4%
9
Frontiers in Physiology
106 papers in training set
Top 0.6%
2.9%
50% of probability mass above
10
Journal of the American Heart Association
140 papers in training set
Top 2%
2.2%
11
eLife
5828 papers in training set
Top 43%
2.2%
12
Biomedical Optics Express
95 papers in training set
Top 0.5%
2.2%
13
Frontiers in Neurology
102 papers in training set
Top 2%
2.0%
14
European Journal of Nuclear Medicine and Molecular Imaging
20 papers in training set
Top 0.1%
1.8%
15
Frontiers in Cardiovascular Medicine
53 papers in training set
Top 1%
1.8%
16
Circulation
74 papers in training set
Top 1%
1.6%
17
MethodsX
16 papers in training set
Top 0.1%
1.2%
18
Frontiers in Endocrinology
58 papers in training set
Top 0.9%
1.2%
19
Heart
11 papers in training set
Top 0.7%
1.2%
20
eBioMedicine
183 papers in training set
Top 4%
1.2%
21
Journal of Clinical Medicine
97 papers in training set
Top 4%
1.1%
22
Heart Rhythm
23 papers in training set
Top 0.5%
1.0%
23
European Heart Journal
22 papers in training set
Top 1%
0.9%
24
European Heart Journal - Digital Health
18 papers in training set
Top 0.9%
0.9%
25
The Journal of Heart and Lung Transplantation
11 papers in training set
Top 0.4%
0.9%
26
Journal of Medical Imaging
11 papers in training set
Top 0.3%
0.9%
27
Ultrasound in Medicine & Biology
10 papers in training set
Top 0.4%
0.6%
28
Journal of Neurology
28 papers in training set
Top 1%
0.6%
29
Frontiers in Pharmacology
111 papers in training set
Top 3%
0.6%
30
Open Heart
21 papers in training set
Top 1%
0.6%