Back

Diagnostic Concordance of Immediate Versus 1-Hour Technetium-99m Hydroxydiphosphonate Scintigraphy in Suspected Transthyretin Amyloid Cardiomyopathy

Costa, A.; Suits, A.; Miller, J.; Ferencik, M.; German, D. M.; Shalen, E. F.; Choudhary, G.; Szidonya, L.; Nguyen, M.; Mallak, N.; Obrzut, S.; Masri, A.

2026-06-17 cardiovascular medicine
10.64898/2026.06.16.26355752 medRxiv
Show abstract

Background Bone-avid tracer myocardial scintigraphy for the diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM) has traditionally employed imaging at one or 3-hour intervals. Technetium-99m hydroxydiphosphonate (99mTc-HDP) has unique characteristics that may enable earlier imaging. We investigated the diagnostic concordance of immediate versus 1-hour acquisitions. Methods Consecutive patients with suspected ATTR-CM underwent planar imaging and SPECT/CT immediately and at 1-hour following the administration of 99mTc-HDP. Perugini grades and heart to contralateral lung (H/CL) ratios were assessed. Target-to-background ratios (TBRs) were calculated on the SPECT/CT acquisitions using the left ventricular (LV) septum and three background regions: aorta, LV blood-pool, and vertebrae. We assessed diagnostic concordance using Cohen's Kappa ({kappa}), temporal stability using paired t-tests, and correlation between timepoints using Pearson's coefficient (r). The 1-hour SPECT/CT interpretation served as the protocol reference standard. Results Forty-eight patients (83% male; median age, 80 [73-85] years) were evaluated. One-hour SPECT/CT identified 19 positive and 29 negative cases. Immediate SPECT/CT demonstrated 100% diagnostic concordance with the 1-hour reference standard ({kappa} = 1.000; 95% CI: 1.00 to 1.00; p < 0.001). The LV septum/LV Blood-Pool TBR showed the highest correlation (r = 0.956; 95% CI: 0.922 to 0.975; p < 0.001). The LV Septum/Aorta TBR demonstrated high correlation (r = 0.918; 95% CI: 0.857 to 0.953; p < 0.001) and remained stable in the ATTR-negative cohort (-0.02; 95% CI: -0.08 to 0.04; p = 0.54). Significant decrease in the LV Septum/Vertebrae TBR in the ATTR-negative (-0.55; 95% CI: -0.64 to -0.47; p < 0.001) and ATTR-positive cohorts (-1.14; 95% CI: -1.39 to -0.89; p < 0.001) was observed. Conclusions Immediate 99mTc-HDP SPECT/CT is diagnostically concordant with standard 1-hour protocols. By leveraging SPECT/CT and the favorable kinetics of 99mTc-HDP, immediate-phase imaging can accurately reproduce 1-hour acquisitions in cases of suspected ATTR-CM. This expedited approach may improve nuclear laboratory throughput and patient satisfaction.

Matching journals

The top 9 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.