Diagnostic Concordance of Immediate Versus 1-Hour Technetium-99m Hydroxydiphosphonate Scintigraphy in Suspected Transthyretin Amyloid Cardiomyopathy
Costa, A.; Suits, A.; Miller, J.; Ferencik, M.; German, D. M.; Shalen, E. F.; Choudhary, G.; Szidonya, L.; Nguyen, M.; Mallak, N.; Obrzut, S.; Masri, A.
Show abstract
Background Bone-avid tracer myocardial scintigraphy for the diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM) has traditionally employed imaging at one or 3-hour intervals. Technetium-99m hydroxydiphosphonate (99mTc-HDP) has unique characteristics that may enable earlier imaging. We investigated the diagnostic concordance of immediate versus 1-hour acquisitions. Methods Consecutive patients with suspected ATTR-CM underwent planar imaging and SPECT/CT immediately and at 1-hour following the administration of 99mTc-HDP. Perugini grades and heart to contralateral lung (H/CL) ratios were assessed. Target-to-background ratios (TBRs) were calculated on the SPECT/CT acquisitions using the left ventricular (LV) septum and three background regions: aorta, LV blood-pool, and vertebrae. We assessed diagnostic concordance using Cohen's Kappa ({kappa}), temporal stability using paired t-tests, and correlation between timepoints using Pearson's coefficient (r). The 1-hour SPECT/CT interpretation served as the protocol reference standard. Results Forty-eight patients (83% male; median age, 80 [73-85] years) were evaluated. One-hour SPECT/CT identified 19 positive and 29 negative cases. Immediate SPECT/CT demonstrated 100% diagnostic concordance with the 1-hour reference standard ({kappa} = 1.000; 95% CI: 1.00 to 1.00; p < 0.001). The LV septum/LV Blood-Pool TBR showed the highest correlation (r = 0.956; 95% CI: 0.922 to 0.975; p < 0.001). The LV Septum/Aorta TBR demonstrated high correlation (r = 0.918; 95% CI: 0.857 to 0.953; p < 0.001) and remained stable in the ATTR-negative cohort (-0.02; 95% CI: -0.08 to 0.04; p = 0.54). Significant decrease in the LV Septum/Vertebrae TBR in the ATTR-negative (-0.55; 95% CI: -0.64 to -0.47; p < 0.001) and ATTR-positive cohorts (-1.14; 95% CI: -1.39 to -0.89; p < 0.001) was observed. Conclusions Immediate 99mTc-HDP SPECT/CT is diagnostically concordant with standard 1-hour protocols. By leveraging SPECT/CT and the favorable kinetics of 99mTc-HDP, immediate-phase imaging can accurately reproduce 1-hour acquisitions in cases of suspected ATTR-CM. This expedited approach may improve nuclear laboratory throughput and patient satisfaction.
Matching journals
The top 9 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- PET/CT and SPECT/CT imaging of 90 Y hepatic radioembolization at therapeutic and diagnostic activity levels: anthropomorphic phantom study 90%
- Internal calibration for opportunistic computed tomography muscle density analysis 89%
- Accuracy of deep learning based computed tomography diagnostic system of COVID-19: a consecutive sampling external validation cohort study 89%
Similar papers in this journal
- Referral for Cardiac Amyloidosis in Patients who underwent Transcatheter Aortic Valve Replacement: Result of Quality Outcome Project 90%
- Effects of contrast-medium and vertebral measurement level on computed tomography-based body composition parameters of skeletal muscle and adipose tissue 89%
- “This is a quiz” Premise Input: A Key to Unlocking Higher Diagnostic Accuracy in Large Language Models 87%
Similar papers in this journal
- Reduced stress perfusion in myocardial infarction with nonobstructive coronary arteries 91%
- Left ventricular mass and global wall thickness – prognostic utility and characterization of left ventricular hypertrophy 90%
- 68Ga-Bisphosphonates for the Imaging of Extraosseous Calcification by Positron Emission Tomography 90%
Similar papers in this journal
- Prognostic value of compact myocardial thinning in patients with left ventricular non-compaction 88%
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 88%
- Association of left atrial structure and function with cognitive function among adults with metabolic syndrome 87%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.