Development of a Multidose Irradiation Protocol for Clonogenic Assays in Cell Culture Plates
Medina, B. H.; Andres, P.; Negrin, L.; Biolatti, L. V.; Destri, S.; Mazzitelli-Fuentes, L.
Show abstract
PurposeIn vitro experimental radiobiology is a fundamental tool for understanding the cellular and molecular mechanisms involved in the response to ionizing radiation. Conventional experimental designs require separate irradiations to achieve different absorbed doses, thereby introducing experimental variability between irradiation sessions due to inter-session variability in both culture conditions and irradiation geometry. Here, we developed a multidose irradiation system for multiwell cell culture plates that enables the simultaneous delivery of three distinct dose levels within a single plate, thereby reducing resource consumption and operating time MethodsThe system was designed using a clinical linear accelerator delivering 6 MV X-rays and a 3D conformal irradiation approach based on CT imaging. Dose calculations for 200, 400 and 600 cGy were performed using Monaco Version 5.11. The irradiation geometry was optimized to achieve distinct and well-separated dose regions while preserving dose uniformity within each dose level. Treatment planning showed good agreement between estimated and prescribed dose levels, with mean dose deviation ranging from 0.35-1.63%. Physical verification using TLDs and radiochromic films demonstrated high dosimetric accuracy, showing deviations of 0.5-1.0% and 0.57-3.0%, respectively, expressed as the deviation of the measured mean dose from the nominal administered dose levels. Biological assessment included clonogenic assays in human tumor cell lines and a metabolic assay. Clonogenic assays showed a high concordance between the multidose and single-dose irradiation, with comparable linear-quadratic model fits (extra sum-of-squares F-test, p = 0.0923), confirming preservation of the intrinsic radiobiological response under simultaneous irradiation. ConclusionsThese results support the reliability of the proposed multidose irradiation system for in vitro radiobiology. This robust and reproducible system enables efficient characterization of radiobiological parameters.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Dosimetric and biologic intercomparison between electron and proton FLASH beams 98%
- First demonstration of the FLASH effect with ultrahigh dose-rate high-energy X-rays 96%
- Evaluation of indirect damage and damage saturation effects in dose-response curves of hypofractionated radiotherapy of early-stage NSCLC and brain metastases 95%
Similar papers in this journal
Similar papers in this journal
- Redefining FLASH RT: the impact of mean dose rate and dose per pulse in the gastrointestinal tract 98%
- Discordance in acute gastrointestinal toxicity between synchrotron-based proton and linac-based electron ultra-high dose rate irradiation 97%
- FLASH Bragg-peak irradiation with a therapeutic carbon ion beam: first in vivo results 96%
Similar papers in this journal
- DNA damage and somatic mutations in mammalian cells after irradiation with a nail polish dryer 91%
- Hemoxygenase-1 as a key mediator of acute radiation pneumonitis revealed in a human lung alveolus-on-a-chip 91%
- Integration of machine learning and genome-scale metabolic modeling identifies multi-omics biomarkers for radiation resistance 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.