Back

Microbial Influenced Corrosion: A Novel Initiator of In Vivo Spine Rod Fracture

Ayers, R.; Guo, X.; Kleck, C.; Harris, J.; Gorman, B.; Rogers, M.; Ou-Yang, D.; Burger, E.; Wessell, N.; Damioli, L.; Ackert-Bicknell, C. L.

2026-06-06 bioengineering
10.64898/2026.06.02.729376 bioRxiv
Show abstract

Spine rod catastrophic failure/rod fracture after implantation is estimated to occur in [~]10% of all cases worldwide with this rate remaining consistent for more than 20 years. To accommodate the spine mechanical environment, metal alloys such as austenitic stainless steels, cobalt-chromium-molybdenum alloys, and /{beta} type titanium alloys such are used as they have a high resistance to fatigue failure. The work presented herein addresses the gap in understanding about what happens in a laboratory environment versus what is happening in human patients that results in metal leaching into tissues as well as a shortened lifespan of a spine rod in a patient population that is not capable of breaking these spine rods from purely mechanical means. Eighty-five (N=85) patients (51 female - 62.9 {+/-} 13.5 years old, 34 male - 62.7 {+/-} 10.9 years old) who had spine revision surgery due to patient mechanical issues, such as loss of sagittal or coronal balance, pain, pedicle screw loosening, hardware associated infection were included in this study. All explanted rods had optical indications of surface modification that were not the result of mechanical damage, e.g. gouges, scratches, notches. The presence of Ti6Al4V rods increases the presence of local tissue concentrations of elemental Ti (190.98 {+/-} 207.84 g/g (ppm)) in all patients over the amount that would normally be present in patients who never had any titanium based orthopedic device implants (spinous muscle, 13.12 {+/-} 11.43 g/g). PQS, HHQ, and NHQ ToF-SIMS molecular signals were found co-located to corrosion pits as well with AHLs and palmitic acids indicating microbial presence and metabolism in all patients. This suggests that MIC can cause in vivo pitting corrosion resulting on rod failure.

Matching journals

The top 8 journals account for 50% of the predicted probability mass.

1
PLOS ONE
5266 papers in training set
Top 7%
23.2%
2
Scientific Reports
3612 papers in training set
Top 8%
7.6%
3
Acta Biomaterialia
92 papers in training set
Top 0.3%
5.0%
4
Frontiers in Bioengineering and Biotechnology
98 papers in training set
Top 0.3%
4.2%
5
PeerJ
308 papers in training set
Top 2%
3.3%
6
Journal of the Mechanical Behavior of Biomedical Materials
24 papers in training set
Top 0.1%
2.9%
7
Journal of Biomechanical Engineering
20 papers in training set
Top 0.2%
2.9%
8
Advanced Healthcare Materials
85 papers in training set
Top 0.7%
2.5%
50% of probability mass above
9
Biomaterials Advances
22 papers in training set
Top 0.2%
2.5%
10
Science Advances
1243 papers in training set
Top 17%
2.0%
11
Annals of Biomedical Engineering
37 papers in training set
Top 0.4%
2.0%
12
Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
15 papers in training set
Top 0.1%
1.7%
13
Bioengineering
29 papers in training set
Top 0.4%
1.7%
14
Journal of Biomedical Materials Research Part A
20 papers in training set
Top 0.3%
1.6%
15
ACS Applied Bio Materials
24 papers in training set
Top 0.5%
1.4%
16
Pharmaceutics
24 papers in training set
Top 0.5%
1.2%
17
ACS Applied Materials & Interfaces
39 papers in training set
Top 0.7%
1.2%
18
IEEE Transactions on Biomedical Engineering
40 papers in training set
Top 0.7%
1.2%
19
Advanced Science
286 papers in training set
Top 6%
1.2%
20
Journal of Orthopaedic Research
21 papers in training set
Top 0.2%
1.2%
21
Materials Today Bio
20 papers in training set
Top 0.6%
1.1%
22
International Journal of Molecular Sciences
494 papers in training set
Top 12%
1.1%
23
Journal of Advanced Research
14 papers in training set
Top 0.2%
1.1%
24
Advanced Materials Interfaces
10 papers in training set
Top 0.1%
1.1%
25
ChemBioChem
55 papers in training set
Top 1.0%
1.0%
26
Bone
25 papers in training set
Top 0.3%
1.0%
27
Journal of The Royal Society Interface
235 papers in training set
Top 4%
0.9%
28
eLife
5828 papers in training set
Top 63%
0.9%
29
Applied and Environmental Microbiology
339 papers in training set
Top 5%
0.6%
30
Sensors
43 papers in training set
Top 1%
0.6%