Back

Assessing Lipid Core Burden Index with Depolarization-Sensitive Optical Frequency Domain Imaging

Jones, G.; Otsuka, K.; Fujisawa, N.; Yamaura, H.; Matsumoto, K.; Okamoto, A.; Yamaguchi, T.; Shimada, T.; Kagawa, S.; Yamazaki, T.; Akasaka, T.; Bouma, B. E.; Villiger, M.; Fukuda, D.

2026-06-01 cardiovascular medicine
10.64898/2026.05.22.26353889 medRxiv
Show abstract

Background: Quantitative lipid assessment is central to identifying rupture-prone coronary plaques and represents a therapeutic target for lipid-lowering therapy. Near-infrared spectroscopy (NIRS)-derived lipid core burden index (LCBI) is well validated and widely used for detecting lipid-rich lesions. Optical frequency domain imaging (OFDI) is increasingly adopted for guiding percutaneous coronary intervention (PCI) due to its high-resolution structural imaging capabilities. Depolarization-sensitive OFDI (depOFDI) provides intrinsic lipid contrast and may enable combined structural and compositional plaque characterization within a single OFDI-based platform. Objective: To define an OFDI-derived lipid metric and evaluate its agreement with NIRS-derived LCBI. Methods: Thirty-three patients underwent both polarization-sensitive OFDI and NIRS-intravascular ultrasound imaging during PCI. After exclusion of 4 datasets, 29 co-registered pullbacks were analyzed. A signal-to-noise-corrected depolarization metric was used to identify lipid-rich regions and generate depOFDI chemograms. maxLCBI4mm value and location, as well as total LCBI, were computed and compared with NIRS. Results: depOFDI demonstrated strong agreement with NIRS, showing high correlation for maxLCBI4mm (r^2 = 0.862) and total LCBI (r^2 = 0.867), along with strong spatial concordance for the location of the maxLCBI4mm (r^2 = 0.900). Bland-Altman analysis of LCBI4mm showed minimal bias (10.7) with 95% limits of agreement of [81.4 to 102.8]. Conclusions: depOFDI enables accurate quantification of lipid burden alongside the high-resolution structural information inherently provided by OFDI. Because depolarization metrics can be derived from polarization-diverse detection available in many commercial OFDI systems, this approach provides a practical pathway toward comprehensive plaque characterization within existing PCI workflows, without the need for additional imaging modalities.

Matching journals

The top 11 journals account for 50% of the predicted probability mass.

1
Scientific Reports
3102 papers in training set
Top 6%
10.2%
2
Photoacoustics
11 papers in training set
Top 0.1%
6.4%
3
Frontiers in Cardiovascular Medicine
49 papers in training set
Top 0.5%
6.4%
4
Ultrasound in Medicine & Biology
10 papers in training set
Top 0.1%
4.9%
5
Nature Communications
4913 papers in training set
Top 32%
4.9%
6
Circulation
66 papers in training set
Top 0.8%
4.4%
7
Biomedical Optics Express
84 papers in training set
Top 0.4%
3.6%
8
npj Digital Medicine
97 papers in training set
Top 1%
3.3%
9
Frontiers in Neurology
91 papers in training set
Top 2%
2.8%
10
PLOS ONE
4510 papers in training set
Top 44%
2.6%
11
Journal of Biomedical Optics
25 papers in training set
Top 0.2%
2.4%
50% of probability mass above
12
Journal of Clinical Medicine
91 papers in training set
Top 2%
2.1%
13
Diagnostics
48 papers in training set
Top 0.9%
1.8%
14
Atherosclerosis
29 papers in training set
Top 0.7%
1.7%
15
IEEE Transactions on Biomedical Engineering
38 papers in training set
Top 0.5%
1.7%
16
JACC: Clinical Electrophysiology
11 papers in training set
Top 0.2%
1.7%
17
Journal of Translational Medicine
46 papers in training set
Top 0.8%
1.7%
18
NeuroImage: Clinical
132 papers in training set
Top 3%
1.5%
19
Biomaterials
78 papers in training set
Top 0.6%
1.5%
20
American Journal of Physiology-Heart and Circulatory Physiology
32 papers in training set
Top 0.8%
1.3%
21
The American Journal of Cardiology
15 papers in training set
Top 1.0%
1.3%
22
eLife
5422 papers in training set
Top 49%
1.2%
23
Optics Letters
13 papers in training set
Top 0.2%
1.1%
24
Computers in Biology and Medicine
120 papers in training set
Top 3%
1.0%
25
Medical Image Analysis
33 papers in training set
Top 0.8%
1.0%
26
Frontiers in Physiology
93 papers in training set
Top 5%
0.9%
27
BMJ Open
554 papers in training set
Top 11%
0.9%
28
EBioMedicine
39 papers in training set
Top 0.9%
0.8%
29
Journal of Advanced Research
15 papers in training set
Top 0.6%
0.8%
30
NeuroImage
813 papers in training set
Top 5%
0.8%