Back

SmartSpacer: Design, Implementation, and In-Vitro Validation of a Multimodal Sensorized Knee Spacer for Continuous Infection Monitoring in Two-Stage Revision Arthroplasty

Morandell, P.; Dillitzer, C.; Tran, N. B.; Lallinger, V.; Lazic, I.; Burgkart, R.; Hayden, O.

2026-04-29 bioengineering
10.64898/2026.04.24.720557 bioRxiv
Show abstract

Periprosthetic joint infection (PJI) is the leading cause of failure in two-stage revision total knee arthroplasty (TKA). The timing of reimplantation currently relies on subjective clinical assessment, as no established method enables continuous, objective, local monitoring of infection dynamics during the spacer interval. We present the SmartSpacer, a sensorized antibiotic-loaded PMMA knee spacer integrating a miniaturized PCB within the tibial component (65 x 45 x 12 mm). The system incorporates digital temperature sensors, a CMOS camera module, a spectrometer, an inertial measurement unit, and a Bluetooth Low Energy (BLE) 5.2 transceiver. Firmware was developed on Zephyr RTOS with aggressive power management. Validation experiments covered power consumption profiling, BLE signal transmission through air, phantom liquid, and ex-vivo porcine knee tissue, temperature accuracy against a calibrated PT100 reference, and motion detection in seven healthy volunteers across three activity protocols. Firmware optimization reduced quiescent current from 700-850 {micro}A to 8 {micro}A, projecting a battery life exceeding 600 days at a clinically relevant sampling rate of one image and one spectrum per hour -- more than an order of magnitude beyond the maximum spacer implantation duration. BLE connectivity was maintained reliably up to 6 m through tissue-equivalent phantom liquid and up to 8-9 m in open air. Temperature sensors achieved {+/-}0.16 {degrees}C steady-state accuracy with self-heating artefacts below 0.15 {degrees}C. Motion detection scaled proportionally with activity intensity, though inter-subject variability in crutch-walking indicated that patient-specific calibration will be required. The SmartSpacer introduces an in vivo wearable - a temporary, implantable knee spacer providing continuous, wireless, multiparametric monitoring within the joint space. It has the potential to transform two-stage revision arthroplasty from empirically timed to data-driven, individualized clinical decision-making.

Matching journals

The top 11 journals account for 50% of the predicted probability mass.

1
IEEE Transactions on Biomedical Engineering
38 papers in training set
Top 0.1%
10.3%
2
Journal of Neural Engineering
197 papers in training set
Top 0.5%
6.5%
3
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 0.3%
5.0%
4
Nature Communications
4913 papers in training set
Top 35%
4.7%
5
PLOS ONE
4510 papers in training set
Top 33%
4.4%
6
Advanced Science
249 papers in training set
Top 5%
4.0%
7
Science Advances
1098 papers in training set
Top 4%
4.0%
8
Advanced Materials
53 papers in training set
Top 0.7%
3.7%
9
Advanced Healthcare Materials
71 papers in training set
Top 0.7%
3.1%
10
Nature Biomedical Engineering
42 papers in training set
Top 0.4%
3.1%
11
Scientific Reports
3102 papers in training set
Top 40%
3.1%
50% of probability mass above
12
Advanced Functional Materials
41 papers in training set
Top 1.0%
2.7%
13
Annals of Biomedical Engineering
34 papers in training set
Top 0.5%
2.1%
14
Biomaterials
78 papers in training set
Top 0.4%
2.1%
15
Acta Biomaterialia
85 papers in training set
Top 0.4%
1.9%
16
Bioengineering & Translational Medicine
21 papers in training set
Top 0.3%
1.8%
17
Lab on a Chip
88 papers in training set
Top 0.6%
1.7%
18
Communications Biology
886 papers in training set
Top 8%
1.7%
19
npj Digital Medicine
97 papers in training set
Top 2%
1.5%
20
ACS Nano
99 papers in training set
Top 3%
1.4%
21
Biofabrication
32 papers in training set
Top 0.6%
1.3%
22
eLife
5422 papers in training set
Top 51%
1.0%
23
Biosensors and Bioelectronics
52 papers in training set
Top 1%
0.9%
24
HardwareX
16 papers in training set
Top 0.2%
0.9%
25
Journal of NeuroEngineering and Rehabilitation
28 papers in training set
Top 0.9%
0.8%
26
Journal of Visualized Experiments
30 papers in training set
Top 0.7%
0.8%
27
Sensors
39 papers in training set
Top 2%
0.7%
28
Computational and Structural Biotechnology Journal
216 papers in training set
Top 10%
0.7%
29
BMJ Open
554 papers in training set
Top 13%
0.7%
30
Materials Today Bio
18 papers in training set
Top 0.6%
0.7%