Back

Sensorimotor training lightens the perceived weight of body augmentation devices

Radziun, D.; Schippers, A.; Longo, M. R.; Miller, L. E.

2026-04-21 neuroscience
10.64898/2026.04.17.718984 bioRxiv
Show abstract

A distinctive feature of bodily experience is its transparency. During skilled action, our limbs recede from awareness and function as the medium of interaction rather than perceptual objects1. This is reflected in systematic perceptual biases: humans reliably underestimate the weight of their own hands2, potentially reflecting predictive motor processes that modulate self-generated sensory signals. Wearable technologies may test the limits of this perceptual transparency. Exoskeletons and other augmentative devices attach directly to the body, adding mass that must be integrated into sensorimotor control3; yet little is known about how such devices are experienced as they become integrated into the sensorimotor system. Here, we tested whether training with finger-extending exoskeletons alters their perceived weight and whether such changes depend on active use. We developed a Bayesian analytic framework combining individual psychometric modelling with a regression-based decomposition of perceived weight, to partition contributions of the biological hand and attached exoskeletal device. Thirty-four right-handed adults completed a weight-perception task before and after 20 minutes of training with either finger-extending or non-augmenting control devices. Participants compared the perceived weight of their right hand, with or without the exoskeleton, to reference weights suspended from the opposite wrist. Before training, the weight of both the biological hand and the exoskeleton were underestimated to a similar degree ([~]25- 30%), suggesting rapid perceptual integration following attachment. Training selectively increased attenuation of the perceived weight of the finger-extending exoskeleton, with no corresponding change for the biological hand and little evidence for a general training effect. These findings support a two-stage embodiment process in which passive attachment initiates perceptual updating, while sensorimotor training consolidates integration through functional interaction with the device. Perceived weight thus provides a behavioral marker of embodiment, offering insight into how the sensorimotor system integrates wearable augmentative technologies.

Matching journals

The top 7 journals account for 50% of the predicted probability mass.

1
Scientific Reports
3102 papers in training set
Top 1%
18.3%
2
Proceedings of the Royal Society B: Biological Sciences
341 papers in training set
Top 0.8%
8.1%
3
Philosophical Transactions of the Royal Society B: Biological Sciences
53 papers in training set
Top 0.1%
6.3%
4
Philosophical Transactions of the Royal Society B
51 papers in training set
Top 0.6%
6.2%
5
eneuro
389 papers in training set
Top 2%
4.8%
6
Nature Human Behaviour
85 papers in training set
Top 0.6%
4.8%
7
iScience
1063 papers in training set
Top 2%
4.8%
50% of probability mass above
8
Current Biology
596 papers in training set
Top 4%
4.5%
9
Nature Communications
4913 papers in training set
Top 35%
4.3%
10
PLOS Computational Biology
1633 papers in training set
Top 10%
3.5%
11
Science Advances
1098 papers in training set
Top 6%
3.5%
12
eLife
5422 papers in training set
Top 27%
3.5%
13
Communications Biology
886 papers in training set
Top 3%
3.2%
14
Proceedings of the National Academy of Sciences
2130 papers in training set
Top 25%
2.6%
15
Communications Psychology
20 papers in training set
Top 0.1%
1.9%
16
PLOS ONE
4510 papers in training set
Top 56%
1.6%
17
Journal of Neurophysiology
263 papers in training set
Top 0.5%
1.5%
18
npj Digital Medicine
97 papers in training set
Top 3%
1.2%
19
Frontiers in Human Neuroscience
67 papers in training set
Top 3%
0.7%
20
npj Science of Learning
17 papers in training set
Top 0.1%
0.7%
21
npj Microgravity
11 papers in training set
Top 0.3%
0.7%
22
Physical Review Letters
43 papers in training set
Top 0.8%
0.6%