Back

Real-Time Detection of Breast Cancer-Related Lymphedema with Shear-Wave Elastography: The Holder-Optimized Elastography Method

Hoe, Z. Y.; Ding, R.-S.; Chou, C.-P.; Hu, C.; Lee, C.-H.; Tzeng, Y.-D.; Pan, C.-T.; Lee, M.-C.; Lee, E. K.-L.

2026-03-02 radiology and imaging
10.64898/2026.02.25.26344759 medRxiv
Show abstract

BackgroundBreast cancer-related lymphedema (BCRL) is a common complication following breast cancer treatment. While lymphoscintigraphy is considered the diagnostic gold standard, it is unsuitable for routine periodic monitoring or assessment of treatment efficacy. Shear wave elastography (SWE) offers a possible alternative, but traditional modes of operation limit its potential. Proposed SolutionsThe Holder-Optimized Elastography (HOE) method is introduced to eliminate pressure issues introduced by manual operation of ultrasound probes by stabilizing them above the cutis. MethodsThe HOE method was used to acquire ARFI images of high-velocity areas (HVAs, with shear wave velocity greater than 7 m/s) in limbs with and without BCRL (as confirmed and characterized by lymphoscintigraphy) in two cohorts of 15 and 125 patients. ResultsThe HOE method enabled ARFI elastography to directly and consistently visualize the effects caused by both obstructed lymphatic vessels and intraluminal lymphatic fluid as HVAs, whereas traditional hand-held methods did not. Inter-limb differences in HVA burden showed moderate diagnostic performance for detecting BCRL and grading obstruction with modest sensitivity. However, there was systematic underestimation of both early and confluent advanced lesions. ConclusionHOE-based HVA imaging has potential for rapid and non-invasive monitoring of lymphedema course and treatment response and may serve as a useful adjunct to existing diagnostic tools for BCRL. However, further technical refinements and quantitative analytic methods will be required to fully exploit the richer SWV information provided by HOE and to enhance the diagnostic utility of HVAs. Summary StatementThe Holder-Optimized Elastography method ("HOE" method) increases the diagnostic capability of ARFI elastography for breast cancer-related lymphedema, allowing for the non-invasive detection of some lymphatic obstructions but not all. Key ResultsThe Holder-Optimized Elastography (HOE) method revealed the effects caused by fluid-filled lymphatic vessels as "High-Velocity Areas" (HVAs), which are difficult to detect by conventional methods. HVA counts for detecting lymphedema (any obstruction vs. no obstruction) showed high specificity (0.86-1.00) but low sensitivity (0.57-0.67). Conversely, HVA counts for staging lymphedema (i.e. total vs. partial obstruction) showed high sensitivity (up to 1.00) but low specificity (0.48-0.66). The inter-limb difference of HVAs counted in whole-limb scans between affected and unaffected limbs (aka, the "Global Mean Difference") provided the most balanced diagnostic performance (sensitivity 0.67-0.79, specificity 0.88-0.89).

Matching journals

The top 6 journals account for 50% of the predicted probability mass.

1
Scientific Reports
3102 papers in training set
Top 1%
18.0%
2
Diagnostics
48 papers in training set
Top 0.1%
10.7%
3
PLOS ONE
4510 papers in training set
Top 23%
7.4%
4
Ultrasound in Medicine & Biology
10 papers in training set
Top 0.1%
7.0%
5
Journal of Magnetic Resonance Imaging
14 papers in training set
Top 0.1%
5.0%
6
Frontiers in Physiology
93 papers in training set
Top 2%
2.8%
50% of probability mass above
7
European Radiology
14 papers in training set
Top 0.3%
2.8%
8
Frontiers in Oncology
95 papers in training set
Top 1%
2.7%
9
Photoacoustics
11 papers in training set
Top 0.1%
2.5%
10
Cancers
200 papers in training set
Top 2%
2.1%
11
Frontiers in Endocrinology
53 papers in training set
Top 0.9%
1.9%
12
Frontiers in Artificial Intelligence
18 papers in training set
Top 0.2%
1.7%
13
Magnetic Resonance in Medicine
72 papers in training set
Top 0.4%
1.7%
14
eBioMedicine
130 papers in training set
Top 1%
1.7%
15
Nature Communications
4913 papers in training set
Top 51%
1.7%
16
Imaging Neuroscience
242 papers in training set
Top 2%
1.7%
17
Biomedical Optics Express
84 papers in training set
Top 0.7%
1.5%
18
PLOS Computational Biology
1633 papers in training set
Top 18%
1.4%
19
Computers in Biology and Medicine
120 papers in training set
Top 3%
1.3%
20
Annals of Biomedical Engineering
34 papers in training set
Top 0.9%
1.1%
21
Breast Cancer Research
32 papers in training set
Top 0.4%
1.0%
22
Medical Physics
14 papers in training set
Top 0.5%
0.9%
23
Analytical Biochemistry
26 papers in training set
Top 0.1%
0.9%
24
Science Translational Medicine
111 papers in training set
Top 5%
0.9%
25
eLife
5422 papers in training set
Top 55%
0.8%
26
PLOS Digital Health
91 papers in training set
Top 3%
0.8%
27
Journal of Medical Imaging
11 papers in training set
Top 0.3%
0.8%
28
Medicine & Science in Sports & Exercise
15 papers in training set
Top 0.4%
0.8%
29
NeuroImage: Clinical
132 papers in training set
Top 4%
0.7%
30
BMJ Open
554 papers in training set
Top 13%
0.7%