Back

Characterizing MINFLUX imaging performance with DNA origami

Clowsley, A. H.; Bokhobza, A. F. E.; Janicek, R.; Kołataj, K.; Bleuer, G.; Di Michele, L.; Acuna, G. P.; Soeller, C.

2026-02-24 biophysics
10.64898/2026.02.24.707670 bioRxiv
Show abstract

MINFLUX, a second-generation super-resolution technique, can localize fluorescent markers approaching single-nanometer precision in three dimensions. Similar to previous super-resolution methodologies, the extended duration of acquisitions can result in drift that needs accurate correction to enable proper analysis and interpretation of the collected data. Here, we use DNA origami, housing sites of known spatial distribution fitted with repeat-domain docking strands for DNA-PAINT imaging to characterize imaging performance over extended duration MINFLUX acquisitions (6-20 h). Repeat-domain docking strands overcome site-loss and reveal residual drift in prolonged MINFLUX 3D acquisitions that we correct with an algorithm exploiting time-correlated shifts of localizations around identified DNA origami sites. Following correction of residual drift the site precision, i.e. the scatter of localizations around sites, is [~]2 nm in all directions. Comparison of site precision from extended repeat-domain docking strands with site precision from standard short 8-10 nucleotide docking strands exhibits no detectable loss of site precision. By adding DNA origami structures to mounted biological samples we apply our approach to the imaging of the cardiac ryanodine receptor 2 in cryosectioned heart tissue. The data suggests that for these protein targets single domain markers with repeat domain docking strands may be directly used for residual drift correction, simplifying sample preparation and acquisition protocols.

Matching journals

The top 7 journals account for 50% of the predicted probability mass.

1
Scientific Reports
3102 papers in training set
Top 3%
14.0%
2
Biomedical Optics Express
84 papers in training set
Top 0.1%
14.0%
3
Nature Communications
4913 papers in training set
Top 25%
7.0%
4
Optica
25 papers in training set
Top 0.2%
6.2%
5
Biophysical Journal
545 papers in training set
Top 1%
4.1%
6
PLOS ONE
4510 papers in training set
Top 37%
3.9%
7
Nature Methods
336 papers in training set
Top 3%
3.9%
50% of probability mass above
8
ACS Photonics
13 papers in training set
Top 0.1%
3.5%
9
Journal of Microscopy
18 papers in training set
Top 0.1%
2.7%
10
eLife
5422 papers in training set
Top 34%
2.3%
11
Methods
29 papers in training set
Top 0.1%
2.3%
12
Journal of Biophotonics
16 papers in training set
Top 0.2%
2.0%
13
Biophysical Reports
36 papers in training set
Top 0.2%
1.7%
14
ACS Sensors
45 papers in training set
Top 0.8%
1.7%
15
Optics Letters
13 papers in training set
Top 0.2%
1.7%
16
Cell Reports Methods
141 papers in training set
Top 3%
1.6%
17
IUCrJ
29 papers in training set
Top 0.2%
1.3%
18
ACS Nano
99 papers in training set
Top 3%
1.2%
19
Development
440 papers in training set
Top 2%
1.2%
20
Communications Biology
886 papers in training set
Top 15%
1.2%
21
Journal of Biomedical Optics
25 papers in training set
Top 0.6%
0.9%
22
Nucleic Acids Research
1128 papers in training set
Top 18%
0.7%
23
Nano Letters
63 papers in training set
Top 3%
0.7%
24
Nature Biotechnology
147 papers in training set
Top 8%
0.7%
25
Journal of Neuroscience Methods
106 papers in training set
Top 2%
0.7%
26
Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
12 papers in training set
Top 0.1%
0.7%
27
Journal of Structural Biology
58 papers in training set
Top 2%
0.7%
28
The Journal of Physical Chemistry B
158 papers in training set
Top 2%
0.7%
29
Proceedings of the National Academy of Sciences
2130 papers in training set
Top 45%
0.7%
30
Neurophotonics
37 papers in training set
Top 0.7%
0.7%