Back

Adapting the OpenFlexure Microscope for Affordable Live-Cell Imaging

Malcolm, J. R.; Physouni, O.; Lacy, S.; Bentley, M.; Howarth, S. P.; MacDonald, S.; Droop, A. P.; Powell, B. P.; Wiggins, L.; Brackenbury, W. J.; O'Toole, P. J.

2026-02-03 cell biology
10.64898/2026.02.02.703252 bioRxiv
Show abstract

Live-cell imaging (LCI) provides researchers the opportunity to understand biological phenomena at a temporal resolution and is achieved using dedicated imaging systems. These studies enable insight into dynamic phenotypic changes occurring in cells, which may otherwise be missed when studying fixed samples. Access to advanced microscopy is disproportionately available to researchers in high-income countries, whereas researchers in low-to middle-income countries (LMICs) are severely underrepresented in the adoption of such technologies. A major barrier to the dissemination of advanced microscopy centres around economic inequalities, with the cost of high-end imaging systems often being prohibitively expensive. Recognition of such disparities has motivated the wider microscopy community to manufacture frugal microscopes that are accessible to researchers in resource-constrained settings. The OpenFlexure Microscope (OFM) is an open source, customisable, 3D-printed microscope suitable for medical research and field-diagnostics. We have made adaptations to the OFM to enable its use for live-cell imaging in humid tissue culture incubators. By moving major electronic components outside of the microscope, we remove the risk of corrosion of the Raspberry Pi and Sangaboard used to operate the instrument. We tested four common 3D-printing polymer materials for increased thermal robustness and found ASA is the best plastic to print the main body of the microscope, offering both durability and image stability in 24- to 48-hour time course experiments. We have also created an optional 3D-printable weighted-hammock system to reduce external vibration artefacts during image acquisition. Critically, electronic modifications included custom extension cables from the motors and camera to the Raspberry Pi and Sangaboard, and the inclusion of 22 ohm ({Omega}) resistors to reduce the current to the stepper motors, preventing detrimental temperature increases inside sealed incubators during prolonged powering of the instrument. To remove dependence on WiFi connections for setting up timelapse experiments, we generated a simple application with a graphical user interface (GUI) that can be installed locally on a Raspberry Pi and is specifically designed for setting up timelapse experiments without extensive computational knowledge or experience. We validated our LCI-OFM adaptations with a 48-hour treatment of MDA-MB-231 breast cancer cells with the chemotherapeutic drug docetaxel, showcasing how the modified microscope can seamlessly feed into established bioimaging pipelines and generate biologically meaningful results. For researchers in LMICs, this adapted LCI-OFM provides new opportunities to study locally-relevant health challenges with timelapse microscopy, enabling deeper insight into biological dynamics and supporting the generation of preliminary data critical for securing grant funding and access to more advanced imaging systems in purpose-built regional imaging hubs.

Matching journals

The top 6 journals account for 50% of the predicted probability mass.

1
Journal of Microscopy
18 papers in training set
Top 0.1%
15.0%
2
HardwareX
16 papers in training set
Top 0.1%
10.3%
3
Biomedical Optics Express
84 papers in training set
Top 0.2%
7.0%
4
Optica
25 papers in training set
Top 0.2%
6.5%
5
Optics Express
23 papers in training set
Top 0.1%
6.5%
6
PLOS ONE
4510 papers in training set
Top 30%
5.0%
50% of probability mass above
7
Scientific Reports
3102 papers in training set
Top 31%
4.0%
8
Lab on a Chip
88 papers in training set
Top 0.4%
3.1%
9
Advanced Biology
29 papers in training set
Top 0.1%
3.1%
10
Nature Communications
4913 papers in training set
Top 42%
3.1%
11
Journal of Biomedical Optics
25 papers in training set
Top 0.3%
1.9%
12
Journal of Biophotonics
16 papers in training set
Top 0.2%
1.9%
13
Communications Biology
886 papers in training set
Top 6%
1.9%
14
Light: Science & Applications
16 papers in training set
Top 0.3%
1.8%
15
SLAS Technology
11 papers in training set
Top 0.1%
1.8%
16
Journal of Structural Biology
58 papers in training set
Top 0.8%
1.5%
17
Cell Reports Methods
141 papers in training set
Top 3%
1.3%
18
ACS Sensors
45 papers in training set
Top 1%
0.9%
19
Journal of Cell Biology
333 papers in training set
Top 4%
0.9%
20
Nature Methods
336 papers in training set
Top 5%
0.9%
21
Biosensors and Bioelectronics
52 papers in training set
Top 1%
0.8%
22
Frontiers in Cell and Developmental Biology
218 papers in training set
Top 8%
0.8%
23
Biophysical Journal
545 papers in training set
Top 5%
0.8%
24
iScience
1063 papers in training set
Top 33%
0.7%
25
Advanced Science
249 papers in training set
Top 19%
0.7%
26
eLife
5422 papers in training set
Top 61%
0.7%
27
Laboratory Investigation
13 papers in training set
Top 0.3%
0.7%
28
Methods in Ecology and Evolution
160 papers in training set
Top 2%
0.7%
29
Sensors
39 papers in training set
Top 2%
0.5%
30
Development
440 papers in training set
Top 4%
0.5%