Resolving near-micron scale features within a whole sheep head using Hierarchical Phase-Contrast Tomography
Urban, T.; Brunet, J.; Didziokas, M.; Chourrout, M.; Keenlyside, A.; Orsine Murtas Dias, K.; MIRONE, A.; Bellier, A.; Dejea, H.; Lamalle, L.; de Bakker, B.; Petrushkin, H.; Moazen, M.; Walsh, C.; Lee, P. D.; Tafforeau, P.
Show abstract
BackgroundHierarchical Phase-Contrast Tomography (HiP-CT) was developed to image ex vivo intact human soft-tissue organs with local near-micron scale resolution. PurposeWe demonstrate the application of HiP-CT in combination with the recently developed Eikonal Phase Retrieval (EPR) for resolving anatomical features in large hard and soft tissue structures on a sheep head, and show the applicability for zooming to resolve anatomical features with near-micron scale resolution. Materials and MethodsWe imaged an entire skinned sheep head prepared in 70 % ethanol with HiP-CT at an isotropic voxel size of 16.5 {micro}m using the recently developed Eikonal Phase Retrieval (EPR) to reduce artefacts from bones. Local tomography zooms were taken in regions of interest: the eye (4.23 {micro}m voxels) and the coronal suture (2.20 {micro}m voxels). To compare to clinical imaging, we acquired T2-weighted MRI and CT of the sheep head and evaluated the contrast-to-noise ratio for differentiation of white and grey matter in the brain for all modalities. Further evaluations on HiP-CT images include structure tensor analysis for structural orientation in the brain as well as fibre tracking in the coronal suture. ResultsHiP-CT combined with EPR achieved high contrast for both hard and soft tissue. Comparison to MRI showed similar soft-tissue contrast, but much higher spatial resolution. Structure tensor analysis in the brain revealed the orientation of the major white matter bundles. In the eye, near-micron scale features such as retinal layers and the bundles in the optic nerve were visualized. Fiber tracking allowed analysis of the orientation of collagen fiber bundles in the coronal suture. ConclusionThis work highlights the potential of HiP-CT to image a complete sheep head, ex vivo, and hierarchically zoom without sectioning to resolve few-microns features locally, enabling comprehensive three-dimensional visualization of intricate cranial structures and their spatial interrelations. Summary statementTechnical developments in HiP-CT enable ex vivo X-ray imaging of an intact sheep head with local resolution to near-micron scale, demonstrating future viability on a human head. Key resultsO_LIA whole sheep head was imaged with synchrotron-based hierarchical phase-contrast tomography coupled with Eikonal Phase-retrieval with 16.5 {micro}m isotropic voxels. C_LIO_LIThe high contrast for both hard and soft tissue enabled differentiation of brain white and grey matter, the optic nerve and bone features within the skull. C_LIO_LILocal tomography zoom scans in an eye (4.23 {micro}m voxels) and coronal suture (2.20 {micro}m voxels) allowed visualization and analysis of near-micron sized features. C_LI
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- In-vivo monitoring and quantification of breast cancer growth dynamics with non-invasive intravital mesoscopic fluorescence molecular tomography 91%
- cryoTIGER: Deep-Learning Based Tilt Interpolation Generator for Enhanced Reconstruction in Cryo Electron Tomography 90%
- Measuring human cerebral blood flow and brain function with fiber-based speckle contrast optical spectroscopy system 90%
Similar papers in this journal
- Automated joint skull-stripping and segmentation with Multi-Task U-Net in large mouse brain MRI databases 93%
- Myelinated fiber labeling and orientation mapping of the human brain with light-sheet fluorescence microscopy 93%
- 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.