Thermoacoustic ultrasound assessment of liver steatosis - a novel approach for MASLD diagnosis

Cho, J. H.; Bull, C. M.; Thornton, M.; Gao, J.; Rubin, J. M.; Steinberg, I.

2025-12-15 gastroenterology
10.64898/2025.12.12.25342082 medRxiv
Show abstract

Background/ObjectivesMetabolic Dysfunction-Associated Steatotic Liver Disease (MASLD) is a global health crisis, but current diagnostics are limited. Liver biopsy is invasive, magnetic resonance imaging-proton density fat fraction (MRI-PDFF) is expensive, and quantitative ultrasound methods are low-accuracy, especially in patients with a high body mass index (BMI). This study introduces a novel thermo-acoustic (TA) method that generates ultrasound signals based on tissue electrical conductivity, where lean tissue (high in water and electrolytes) absorbs more radio-frequency (RF) energy than fatty tissue, providing a direct molecular contrast for fat. MethodsA prospective, cross-sectional feasibility study compared a new thermo-acoustic fat fraction (TAFF) score with the reference standard MRI-PDFF in 40 subjects with suspected fatty liver disease. Bland Altman analysis, Deming regression, and Binary classification performance were tested. To establish system stability, a dedicated Repeatability and Reproducibility (R&R) study (N = 14) evaluated inter-operator and intra-operator consistency using an Intraclass Correlation Coefficient (ICC) derived from a two-way random-effects ANOVA model. ResultsTAFF estimates demonstrated a substantial correlation (r =0.89) with MRI-PDFF and an average absolute error of 3.04% fat fraction. Classification performance was high, with an Area Under the Receiver Operating Characteristic Curve (AUROC) of 0.92 at the 12% fat fraction threshold and 0.99 at the 20% fat fraction threshold. The R&R study confirmed robust stability (intraclass correlation = 0.89) and a negligible mean inter-operator difference of 0.36%. Estimation errors showed no statistically significant correlation with BMI or other body habitus measurements. ConclusionsThese findings support thermoacoustics potential as an accurate, non-invasive, point-of-care solution that can serve as a new imaging biomarker. By providing predictive values closely aligned with MRI-PDFF across the full MASLD spectrum, TAFF can complement currently available ultrasound methods to address the cost and access constraints of MRI for the assessment, diagnosis, and monitoring of MASLD.

Published in Diagnostics (predicted rank #2) · training set

Matching journals

The top 6 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.