Back

An integrated workflow for structural virology with a 100 keV electron microscope

Pathirage, R.; Dutta, M.; Parsons, R. J.; Lella, M.; Atwood, E.; Zhang, Q. E.; May, A.; Johnson, A.; Huang, X.; Flemming, J.; Kumar, U.; Marayati, B. F.; Spurrier, M. A.; Liu, C.; Zhuo, J.; Song, K.; Devkota Adhikari, R.; Sammour, S.; Ilevbare, V.; Abram, C.; Diaz, M.; Guzman, A.; Rai, J.; Skelly, A. N.; Hogarty, M. P.; Anasti, K.; Purro, M.; Lindsay, M.; Alam, S. M.; Weissman, D.; Herschhorn, A.; Hahn, B. H.; Shaw, G. M.; Sharma, A.; Heaton, N. S.; Edwards, R. J.; Henderson, R.; Denny, T.; Saunders, K. O.; Siliciano, J. D.; Siliciano, R. F.; Haynes, B. F.; Janowska, K.; Acharya, P.

2025-12-10 biochemistry
10.64898/2025.12.08.693081 bioRxiv
Show abstract

Cryo-EM has revolutionized structural biology, especially for flexible and heterogeneous samples, although access to high end microscopes that enable these studies remains a bottleneck. While 300 keV microscopes have been the go-to for high-resolution structural determination, they are expensive and restricted to institutional and national facilities needing specialized expertise, with access falling far short of the demand. Here, we present the user-managed operation of a cheaper 100 keV electron microscope within a structural biology laboratory enabling close integration with protein production, biochemical and biophysical studies. We provide details and considerations for the installation of the microscope, its day-to-day maintenance, and operations. Using virus surface glycoproteins as case studies, we illustrate the workflow from grid screening, data collection, and data processing, and provide examples of data quality. This user-administered setup provides a training platform for researchers at all levels, with beginners in cryo-EM achieving proficiency to independently operate the microscope within a month of regular use and training. We have demonstrated routine high-quality low-resolution reconstructions using a Ceta CMOS camera and high-resolution reconstructions enabling building of atomic models using a Falcon C direct detector. While there are several examples of facilities that manage cryo-EM and individual laboratories leveraging cryo-EM, we provide here the first demonstration of a modern group independently doing both successfully, something that has been talked about frequently but rarely seen.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

1
Acta Crystallographica Section D Structural Biology
59 papers in training set
Top 0.1%
19.0%
2
Journal of Structural Biology
64 papers in training set
Top 0.1%
19.0%
3
IUCrJ
32 papers in training set
Top 0.1%
12.2%
50% of probability mass above
4
Microscopy and Microanalysis
12 papers in training set
Top 0.1%
8.1%
5
Journal of Structural Biology: X
17 papers in training set
Top 0.1%
5.7%
6
Structure
193 papers in training set
Top 0.5%
4.4%
7
eLife
5828 papers in training set
Top 28%
4.1%
8
Journal of Applied Crystallography
14 papers in training set
Top 0.1%
2.0%
9
Journal of Neuroscience Methods
122 papers in training set
Top 1.0%
1.8%
10
Nature Methods
385 papers in training set
Top 5%
1.4%
11
Communications Biology
993 papers in training set
Top 18%
1.4%
12
Journal of Visualized Experiments
34 papers in training set
Top 0.3%
1.4%
13
Nature Communications
5641 papers in training set
Top 48%
1.4%
14
Nature Protocols
33 papers in training set
Top 0.4%
1.1%
15
Journal of Microscopy
20 papers in training set
Top 0.2%
1.1%
16
Wellcome Open Research
67 papers in training set
Top 1%
1.1%
17
Scientific Reports
3612 papers in training set
Top 70%
1.0%
18
Protein Science
246 papers in training set
Top 3%
0.9%
19
Bioinformatics
1204 papers in training set
Top 8%
0.9%
20
Cell Reports Methods
165 papers in training set
Top 4%
0.6%
21
Biological Imaging
15 papers in training set
Top 0.3%
0.6%
22
PLOS ONE
5266 papers in training set
Top 63%
0.6%