Back

Anatomy-guided Inverse-phase-encoding Registration Method for Correcting Susceptibility Artifacts in Sub-millimeter fMRI

Duong, S. T. M.; Phung, S. L.; Bouzerdoum, A.; Boyd Taylor, H.; Puckett, A. M.; Schira, M. M.

2019-09-23 neuroscience
10.1101/779272 bioRxiv
Show abstract

Echo planar imaging (EPI) is a fast and non-invasive magnetic resonance imaging (MRI) technique that supports data acquisition at spatial and temporal resolutions suitable for brain function studies. However, susceptibility artifacts are unavoidable distortions in EPI. These distortions are especially strong in high spatial resolution images and can lead to misrepresentation of brain function in fMRI experiments. A common method for correcting susceptibility artifacts is based on a registration scheme which uses two EPI images acquired using identical sequences but with inverse phase-encoding (PE) directions. In this paper, we present a new method for correcting susceptibility artifacts by integrating a T1-weighted (T1w) image into the inverse-PE based registration, since the T1w structural image is considered as a ground-truth measurement of the brain. Furthermore, the T1w image is used as a criterion to select automatically the regularization parameters of the proposed image registration. Evaluations on two high-resolution EPI-fMRI datasets, acquired at 3T and 7T scanners, confirm that the proposed method provides more robust and sharper corrections and runs faster compared with two other state-of-the-art inverse-PE based susceptibility artifact correction methods, i.e. HySCO and TOPUP.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

1
NeuroImage
813 papers in training set
Top 0.4%
22.3%
2
Magnetic Resonance Imaging
21 papers in training set
Top 0.1%
18.5%
3
Magnetic Resonance in Medicine
72 papers in training set
Top 0.2%
6.3%
4
Human Brain Mapping
295 papers in training set
Top 1%
6.3%
50% of probability mass above
5
Scientific Reports
3102 papers in training set
Top 26%
4.5%
6
Frontiers in Neuroscience
223 papers in training set
Top 1%
4.1%
7
Journal of Neuroscience Methods
106 papers in training set
Top 0.3%
4.1%
8
Imaging Neuroscience
242 papers in training set
Top 1%
3.0%
9
PLOS ONE
4510 papers in training set
Top 44%
2.7%
10
Frontiers in Neuroimaging
11 papers in training set
Top 0.1%
2.3%
11
Neuroinformatics
40 papers in training set
Top 0.4%
1.9%
12
Medical Image Analysis
33 papers in training set
Top 0.6%
1.7%
13
Frontiers in Psychiatry
83 papers in training set
Top 2%
1.7%
14
Aperture Neuro
18 papers in training set
Top 0.2%
1.7%
15
Frontiers in Neuroinformatics
38 papers in training set
Top 0.5%
1.3%
16
NeuroImage: Clinical
132 papers in training set
Top 3%
1.3%
17
Communications Biology
886 papers in training set
Top 13%
1.3%
18
Brain Topography
23 papers in training set
Top 0.3%
0.9%
19
Scientific Data
174 papers in training set
Top 2%
0.9%
20
NMR in Biomedicine
24 papers in training set
Top 0.4%
0.8%
21
Journal of Magnetic Resonance Imaging
14 papers in training set
Top 0.6%
0.7%
22
Biomedical Signal Processing and Control
18 papers in training set
Top 0.6%
0.6%