Anatomy-guided Inverse-phase-encoding Registration Method for Correcting Susceptibility Artifacts in Sub-millimeter fMRI
Duong, S. T. M.; Phung, S. L.; Bouzerdoum, A.; Boyd Taylor, H.; Puckett, A. M.; Schira, M. M.
Show abstract
Echo planar imaging (EPI) is a fast and non-invasive magnetic resonance imaging (MRI) technique that supports data acquisition at spatial and temporal resolutions suitable for brain function studies. However, susceptibility artifacts are unavoidable distortions in EPI. These distortions are especially strong in high spatial resolution images and can lead to misrepresentation of brain function in fMRI experiments. A common method for correcting susceptibility artifacts is based on a registration scheme which uses two EPI images acquired using identical sequences but with inverse phase-encoding (PE) directions. In this paper, we present a new method for correcting susceptibility artifacts by integrating a T1-weighted (T1w) image into the inverse-PE based registration, since the T1w structural image is considered as a ground-truth measurement of the brain. Furthermore, the T1w image is used as a criterion to select automatically the regularization parameters of the proposed image registration. Evaluations on two high-resolution EPI-fMRI datasets, acquired at 3T and 7T scanners, confirm that the proposed method provides more robust and sharper corrections and runs faster compared with two other state-of-the-art inverse-PE based susceptibility artifact correction methods, i.e. HySCO and TOPUP.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- NOise Reduction with DIstribution Corrected (NORDIC) PCA in dMRI with complex-valued parameter-free locally low-rank processing 97%
- Diffusion-Informed Spatial Smoothing of fMRI Data in White Matter Using Spectral Graph Filters 97%
- Improved motion correction of submillimetre 7T fMRI time series with boundary-based registration (BBR) 97%
Similar papers in this journal
- Diffusion MRI Harmonization via Personalized Template Mapping 98%
- Automatic Landmark-guided Bijective Brain Image Registration by Composing Region-based Locally Diffeomorphic Warpings 97%
- Cross-modality image translation of 3 Tesla Magnetic Resonance Imaging to 7 Tesla using Generative Adversarial Networks 97%
Similar papers in this journal
- Simultaneous Confidence Regions for Image Excursion Sets: a Validation Study with Applications in fMRI 97%
- ACID: A Comprehensive Toolbox for Image Processing and Modeling of Brain, Spinal Cord, and Post-mortem Diffusion MRI Data 96%
- Denoising Diffusion MRI: Considerations and implications for analysis 96%
Similar papers in this journal
- Improving 3D Edge Detection for Visual Inspection of MRI Coregistration and Alignment 97%
- Estimation of Laminar BOLD Activation Profiles using Deconvolution with a Physiological Point Spread Function 96%
- A novel 5D brain parcellation approach based on spatio-temporal encoding of resting fMRI data from deep residual learning 95%
Similar papers in this journal
- Estimation of free water-corrected microscopic fractional anisotropy 96%
- Assessing uncertainty in connective field estimations from resting state fMRI activity 96%
- A library for fMRI real-time processing systems in python (RTPSpy) with comprehensive online noise reduction, fast and accurate anatomical image processing, and online processing simulation 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.