Back

Fresh Paraformaldehyde Preserves Thrombus Biochemistry -Infrared Spectroscopy and Secondary Ion Mass Spectrometry Investigation of Pulmonary Artery Thrombi

Moyo, S.; Stepien, E.; Wrobel, A.; Moskal, P.; Skalska, M.; Leszczynski, B.; Stepniewski, J.; Kopec, G.

2025-12-08 biophysics
10.1101/2025.11.17.688840 bioRxiv
Show abstract

BackgroundBiochemical analyses of pulmonary embolism derived thrombi depend critically on fixative quality. ObjectiveTo quantify the impact of paraformaldehyde (PFA) shelf life on thrombus molecular integrity using attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy and time-of-flight secondary ion mass spectroscopy (SIMS) combined with principal component analysis. MethodsTen pulmonary artery thrombi were fixed in either aged PFA (6 months; n = 6) or freshly prepared 4% PFA (n = 4); an in-vitro plasma clot control received the same fresh PFA. Triplicate ATR-FTIR spectra (400-4000 cm-1) were collected and vector-normalized to the Amide I band. ToF-SIMS measurements were performed using a 30 keV Bi primary ion beam Fixative chemistry was assessed by the carbonyl absorbance at 1700 cm-1. ResultsFreshly fixed thrombi displayed narrow Amide I (~1650 cm-1) and Amide II (~1540 cm-1) bands with a higher signal-to-noise ratio (SNR; median 41.8) than aged-PFA samples (18.2; P < .01). Carbonyl absorbance at 1700 cm-1 was markedly higher in fresh PFA. Aged PFA introduces chemical variances of biological samples in low-mass molecule fragments. PCA showed clear separation of fresh versus aged specimens and alignment of fresh thrombi with plasma controls across spectral windows. ConclusionsPFA solutions older than three months markedly deteriorate thrombus biochemical fidelity. ATR-FTIR and ToF-SIMS offer a rapid quality-control assay prior to molecular analyses. Key pointsO_LIPFA stored [&ge;]3 months loses >70% of reactive aldehydes, yielding broad Amide envelopes, attenuated lipid bands and a two fold SNR drop. C_LIO_LIAged PFA introduces chemical variances of biological samples in low-mass molecule fragments. C_LIO_LIPCA of fingerprint, protein or lipid windows cleanly separates aged from fresh fixations (PC1 up to 80% variance). C_LIO_LIA rapid QC workflow (carbonyl absorbance [&ge;]0.25 a.u. plus PCA verification) safeguards molecular integrity irrespective of patient age, DVT history or clinical severity. C_LIO_LIAdopting this workflow will harmonise multi centre clot biorepositories and enhance the reproducibility of proteomic, lipidomic and imaging studies. C_LI

Matching journals

The top 11 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.