Validation of deep learning enabled web based and smartphone optimized application RadAnalyzer to measure vertebral heart size and vertebral left atrial size in dogs
Gordon, S.; Reyes, T.; Baibos-Reyes, T.; Sykes, K. T.; Watson, A.
Show abstract
BackgroundObjective radiographic measures of heart size including vertebral heart size (VHS) and vertebral left atrial size (VLAS) are associated with inter and intra-observer variability when measured by humans. Artificial intelligence (AI) tools including RadAnalyzer are available to measure VHS and VLAS. ObjectivesCompare VHS and VLAS measurements made by web based and smartphone optimized deep learning enabled program, RadAnalyzer, to a trained observer. Animals1058 client-owned dogs, across 80 breeds with a variety of heart sizes and thoracic confirmations. MethodsRetrospective, single center, method comparison study. Pearsons correlation, Bland-Altman plots and Passing-Bablok regression were used to assess agreement. ResultsRadAnalyzer measurements of VHS and VLAS correlated well with the human observers modified measurements (r=0.917 and r=0.873 respectively) and had small mean biases (0.002 and 0.007 vertebrae respectively). Conclusions and clinical importanceRadAnalyzer had clinically insignificant magnitude differences in measurement of VHS and VLAS when compared to a human observer and can therefore be used to assist veterinarians with measuring VHS and VLAS on right lateral radiographs in dogs of all sizes. Future studies comparing AI derived radiographic measures with echocardiographic measures of cardiac size are required.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- {-}CardiOvascular examination in awake Orangutans (Pongo pygmaeus pygmaeus): Low-stress Echocardiography including Speckle Tracking imaging (the COOLEST method) 96%
- Evaluation of plasma N-terminal pro-B-type natriuretic peptide levels in healthy North American Salukis with normal echocardiographic measurements. 95%
Similar papers in this journal
- Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT 94%
- MyoVision-US: an Artificial Intelligence-Powered Software for Automated Analysis of Skeletal Muscle Ultrasonography 93%
- Mechanical Metric for Skeletal Biomechanics Derived from Spectral Analysis of Stiffness matrix 92%
Similar papers in this journal
- Variability of in vivo sarcomere length measures in the upper limb obtained with second harmonic generation microendoscopy 92%
- Feasibility of estimation of aortic wave intensity using non-invasive pressure recordings in the absence of flow velocity in man. 92%
- Demonstration of Patient-Specific Simulations To Assess Left Atrial Appendage Thrombogenesis Risk 90%
Similar papers in this journal
- Factors determining success of the chronically instrumented unanesthetized fetal sheep model of human development: a retrospective cohort study 92%
- Effects of contrast-medium and vertebral measurement level on computed tomography-based body composition parameters of skeletal muscle and adipose tissue 91%
- Referral for Cardiac Amyloidosis in Patients who underwent Transcatheter Aortic Valve Replacement: Result of Quality Outcome Project 91%
Similar papers in this journal
- Correlation Between Chest Computed Tomography And Lung Ultrasonography In Patients With Coronavirus Disease 2019 (COVID-19) 91%
- Strain patterns with ultrasound for improved assessment of abdominal aortic aneurysm vessel wall biomechanics 91%
- Indexing Cerebrovascular Health Using TranscranialDoppler Ultrasound 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.