PAUL glaucoma implant - efficacy and safety: A systematic review and meta-analysis
Hong, C. Y.; Wong, A. B. C.; Hong, C. L.
Show abstract
BackgroundThis systematic review and meta-analysis aim to evaluate the efficacy and safety of the PAUL(R) Glaucoma Implant in reducing intraocular pressure and number of anti-glaucoma medication use in both adult and paediatric populations. MethodsA systematic review was conducted following the PRISMA guidelines. The databases PubMed, Ovid-Embase and Scopus were searched to include studies published between January 2017 and September 2025. Studies were stratified by age and risk of bias was assessed using the Newcastle-Ottawa Scale for observational studies and ROBUST-RCT for randomized trials. Primary outcomes were intraocular pressures and number of glaucoma medications at each follow-up visits. Random effects meta-analyses were performed. Secondary outcome was complications. ResultsTwenty-four studies (twenty adults, four paediatric) comprising 836 eyes were included in our review and meta-analysis. Both adult and paediatric patients showed significant IOP reduction post-surgery, with a mean difference of 17.48 mmHg (95% CI: 14.59, 20.37) and 20.31 mmHg (95% CI: 7.80, 32.82) at 1 week, respectively, and sustained reductions at 12 months. The reduction in glaucoma medications was 79.2% for adults and 71.4% for children at 12 months. Subgroup analyses demonstrated greater IOP reduction in studies conducted in the Middle East. The uses of Mitomycin C did not significantly affect outcomes. ConclusionThe PAUL(R) glaucoma implant showed significant and sustained IOP reductions with reduced need for glaucoma medications. The PAUL(R) glaucoma implant is a promising surgical option for glaucoma management in both adults and children. Further long-term prospective comparative studies are needed to assess long-term efficacies and allow direct comparisons with other glaucoma drainage devices.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- The learning curve of murine subretinal injection among clinically trained ophthalmic surgeons 94%
- Race/ethnicity in relation to incident primary open-angle glaucoma characterized by autonomously determined visual field loss patterns 94%
- Relating Standardized Automated Perimetry Performed with Stimulus Sizes III and V in Eyes With Field Loss due to Glaucoma and NAION 94%
Similar papers in this journal
- Risk Model for Intraoperative Complication during Cataract Surgery Based on Data from 900,000 Eyes – Previous Intravitreal Injection is a Risk Factor 96%
- Macula structural and vascular differences in glaucoma eyes with and without high axial myopia 95%
- Exposure to glucagon-like peptide 1 receptor (GLP-1R) agonists reduces glaucoma risk 94%
Similar papers in this journal
- Increasing frequency of hospital admissions for retinal detachment and vitreo-retinal surgery in England 2000-2018 94%
- Automated vision screening of children using a mobile graphic device 92%
- Evaluation of OCT biomarker changes in treatment-naive neovascular AMD using a deep semantic segmentation algorithm 91%
Similar papers in this journal
Similar papers in this journal
- Automated 360-degree goniophotography with the NIDEK Gonioscope GS-1 for glaucoma 95%
- The evaluation of a web‐based tool for measuring the uncorrected visual acuity and refractive error in keratoconus eyes: a prospective open‐label method comparison study 95%
- Factors predicting the visual outcome of intracorneal ring segment for keratoconus 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.