Developing A Data Pipeline to Quantify Ventilator Waveforms
Sottile, P. D.; Larchick, L.; Stroh, J.; Albers, D.; Smith, B.
Show abstract
AO_SCPLOWBSTRACTC_SCPLOWO_ST_ABSOO_SCPLOWBJECTIVEC_SCPLOWC_ST_ABSTo automatically collect ventilator waveforms and integrate them with curated electronic health record data from thousands of patients to provide the data necessary to analyze the complex interactions between lung injury, patient effort, ventilator dyssynchrony, and ventilator mechanics. Such datasets do not currently exist, hampering the understanding of ventilator trajectories. DO_SCPLOWESIGNC_SCPLOWA prospective, observational study which utilizes a multidisciplinary team of data scientists, biomedical engineers, and clinicians to develop an automated pipeline collecting high-fidelity ventilator waveform data and integrating these data with electronic health record data, including vital signs, sedation and agitation scores, lab results, and medications (drug, dose, and route). Importantly, electronic health record data are collected over a patients entire hospital course, allowing for a complete description of patient trajectories. SO_SCPLOWETTINGSC_SCPLOWThe Medical Intensive Care Unit at the University of Colorado. PO_SCPLOWATIENTSC_SCPLOWAll mechanically ventilated adult patients. IO_SCPLOWNTERVENTIONSC_SCPLOWNone. MO_SCPLOWEASUREMENTSC_SCPLOWAutomated collection of high-fidelity ventilator waveforms and electronic health record data. RO_SCPLOWESULTSC_SCPLOWBetween July 2023 and May 2025, we collected data from 1,116 patients, 968 (87%) of whom had >12 hours of mechanical ventilation. These patients generated 4,767 ventilator days (>13 ventilator years) of analyzable ventilator waveforms and had a median duration of ventilation of 2.6[1.25, 6.06] days. Over 146 million breaths were segmented from the waveforms, of which 49 million breaths were able to fit the linear single-compartment model accurately and had a median compliance of 35.7 [25.2, 45.3] mL/H2O. Electronic health record data was linked to the waveforms to provide 8,511 [3,835, 17,040] records per patient. These data constitute a comprehensive database for studying the effects of mechanical ventilation, patient effort, ventilator dyssynchrony, and key non-ventilator covariates, such as sedation, across a large and heterogeneous cohort of patients. CO_SCPLOWONCLUSIONC_SCPLOWWe created a fully automated data pipeline to continuously collect mechanical ventilation waveform data and integrate it with detailed EHR data to generate a unique, high-fidelity dataset that will be crucial for understanding the complex relationships among lung injury, patient effort, sedation, ventilator dyssynchrony, and ventilator mechanics. KO_SCPLOWEYC_SCPLOW PO_SCPLOWOINTSC_SCPLOWO_ST_ABSQO_SCPLOWUESTIONC_SCPLOWC_ST_ABSTo create an automated data pipeline to collect and integrate continuous ventilator waveform data with electronic health record data. FO_SCPLOWINDINGSC_SCPLOWBetween July 2023 and May 2025, we automatically collected data from 1,116 patients, 968 (87%) of whom received mechanical ventilation for more than 12 hours. MO_SCPLOWEANINGC_SCPLOWThis fully automated data collection pipeline will facilitate advances in understanding the complex relationships between lung injury, patient effort, sedation, ventilator dyssynchrony, and ventilator mechanics.
Matching journals
The top 13 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Identification of physiological adverse events using continuous vital signs monitoring during paediatric critical care transport: a novel data-driven approach 94%
- Use of a Continuous Single Lead Electrocardiogram Analytic to Predict Patient Deterioration Requiring Rapid Response Team Activation 92%
- The High Price of Equity in Pulse Oximetry: A cost evaluation and need for interim solutions 91%
Similar papers in this journal
- PVP1–The People’s Ventilator Project: A fully open, low-cost, pressure-controlled ventilator 94%
- Computational simulation to assess patient safety of uncompensated COVID-19 two-patient ventilator sharing using the Pulse Physiology Engine 92%
- Sharing ventilators in the Covid-19 pandemics. A bench study 92%
Similar papers in this journal
- Validation of a Derived International Patient Severity Algorithm to Support COVID-19 Analytics from Electronic Health Record Data 94%
- Real-Time Electronic Health Record Mortality Prediction During the COVID-19 Pandemic: A Prospective Cohort Study 93%
- Observer: Creation of a Novel Multimodal Dataset for Outpatient Care Research 92%
Similar papers in this journal
- Exploring Associations with Severe Hypoxemic Respiratory Failure in COVID-19 Patients upon Admission: A Model for Severe Hypoxemic Respiratory Failure in 329 Unvaccinated, Hospitalized COVID-19 Patients 92%
- Helmet noninvasive ventilation for COVID-19 patients (Helmet-COVID): study protocol for a multicenter randomized controlled trial 91%
- COVID-19 Advanced Respiratory Care Educational Training Program for Healthcare Workers in Lesotho: An Observational Study 91%
Similar papers in this journal
- Two-way remote monitoring allows effective and realistic provision of home-NIV to COPD patients with persistent hypercapnia 91%
- A new method to measure inter-breath intervals in infants for the assessment of apnoea and respiratory dynamics 91%
- Remote-management of COPD: Evaluating Implementation of Digital Innovation to Enable Routine Care (RECEIVER) – Protocol for a feasibility and service adoption observational cohort study 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.