Effect of Wall Motion Sampling on CFD-Derived Left Atrial Flow Metrics

Stöcker, Y.; Guerrero-Hurtado, M.; Duran, E.; Gonzalo, A.; Ristic, Z.; Telle, A.; Kassar, A.; Haykal, R.; Akoum, N.; Boyle, P. M.; Flores, O.; Augustin, C. M.; del Alamo, J. C.; Garcia-Villalba, M.

2026-07-31 bioengineering
10.1101/2025.10.24.684343 bioRxiv
Show abstract

The temporal resolution of medical imaging sequences used to drive patient-specific computational fluid dynamics (CFD) simulations remains limited, typically providing 10-20 frames per cardiac cycle. Therefore, temporal interpolation to reconstruct left atrial (LA) wall motion and boundary conditions is required, but its impact on hemodynamic predictions has not been systematically characterized. To investigate this, we constructed high-temporal-resolution reference wall-motion data using electromechanical (EM) simulations on five patient-specific atrial geometries with a history of atrial fibrillation. We then generated temporally downsampled datasets to emulate clinical frame rates (5, 10, 20, and 40 frames per cycle) and performed CFD simulations to isolate the effects of temporal undersampling on hemodynamic metrics. The focus was placed on kinetic energy, KE, and residence time, TR, particularly in the left atrial appendage (LAA), where thrombosis is most likely to occur. We employed an immersed boundary method to prescribe the wall motion and computed blood TR through a passive scalar transport equation. Results indicate that while global LA hemodynamic indices were marginally affected by the frame rate (errors < 9%), LAA metrics were more sensitive with errors up to 31% compared to reference values. The results based on 20 and 40 frames per cycle yielded favorable agreement with reference results, while 5-and 10-frame reconstructions showed larger, though not systematically biased, deviations from the reference. Importantly, patient ranking by blood-stasis indices was largely preserved. The analysis suggests that patientspecific LA reconstructions derived from dynamic CT imaging provide a reliable basis for estimating LAA blood-stasis indices. Higher frame rates ([&ge;] 20 per cycle) offer improved quantitative accuracy, while lower temporal resolutions may remain informative for patient stratification purposes, where relative ranking is more relevant than absolute accuracy.

Matching journals

The top 6 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.