Premature Ventricular Contraction-Mediated Ventricular Fibrillation: Clinical characteristics, Application of Machine-Learning Algorithm and Outcomes of Catheter Ablation: Multicentric Case Series
Maan, A.; Stanton, E.; Greydanus, M.; Mann, A.; van de Leur, R.; Khalaph, M.; Sommer, P.; Chatterjee, N. A.; El Hamriti, M.
Show abstract
BackgroundPremature ventricular contractions (PVCs) are common in patients with and without structural heart disease. In a subset of patients, PVCs are associated with malignant ventricular arrhythmias including ventricular fibrillation (VF). There are limited clinical tools available to identify which patients with PVCs are at risk for VF. MethodsWe analyzed data from an international, multi-center cohort of 61 patients who underwent catheter ablation for PVCs (41 with PVC-triggered VF, 20 controls). We evaluated the prevalence of routine 12 lead ECG characteristics in patients with PVC-triggered VF including (a) early repolarization (ER) in inferior/ lateral leads and (b) QRS notching of the sinus beat or PVC. We evaluated whether a machine learning (ML) ECG algorithm (Factor ECG) could discriminate between individuals with PVC-triggered VF and individuals with PVC and no history of VF. Explainability analyses were performed to identify which components of the ECG waveform were associated with risk prediction. ResultsIn 41 patients with PVC-triggered VF, there were a median of 8 ICD shocks/per patient prior to index PVC ablation. The mean coupling interval of the PVC to the antecedent sinus beat was 313{+/-}130 ms. When compared to controls, early repolarization (39% vs. 20%) and QRS notching (71% vs. 25%) were significantly more prevalent in individuals with PVC-triggered VF. After a median ablation of 1 [IQR: 1-3]), 82% of patients remained free of VT/VF and ICD shocks over a median follow up of 400 [90-2490] days. The ML ECG algorithm demonstrated reasonable discrimination of patients with PVC-triggered VF compared to PVC without VF (AUROC 0.85 [0.56-1.0]). Anterior ST segment deviation and left bundle branch like delay of the ECG waveform were salient contributors to ML-based prediction. ConclusionsIn patients with PVC-triggered VF, routine ECG parameters including early repolarization and QRS notching were present in up to two-thirds of patients and were more prevalent compared to individuals with PVC without VF. An ML-based ECG algorithm effectively distinguished between PVC-triggered VF compared to PVC without a history of VF.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Atrial functional substrates for the prediction of atrial fibrillation recurrence after pulmonary vein isolation 97%
- Prognostic value of compact myocardial thinning in patients with left ventricular non-compaction 95%
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 95%
Similar papers in this journal
- Relationship of mild to moderate impairment of left ventricular ejection fraction with fatal ventricular arrhythmic events in cardiac sarcoidosis 96%
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 95%
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 95%
Similar papers in this journal
- Enhancing Ventricular Tachycardia Ablation Outcomes: The Impact Of Functional Mapping In Chagas Cardiomyopathy 97%
- Peri-Procedural Intravascular Hemolysis during Atrial Fibrillation Ablation: A Comparison of Pulsed-Field with Radiofrequency Ablation 96%
- Multicenter analysis of atrioesophageal fistula rates before and after adoption of active esophageal cooling during atrial fibrillation ablation 94%
Similar papers in this journal
- Atrial Fibrillation Catheter Ablation among Cancer Patients: Utilization Trends and In-Hospital Outcomes 95%
- Screening for Right Ventricular Dysfunction in the Emergency Department Using a Smartphone ECG Analysis Application: An External Validation Study with Acute Pulmonary Embolism Patients 92%
- Myocardial performance improvement after iron replacement in heart failure patients: The IRON-PATH II echo-substudy 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.