Development and evaluation of Z-score based aortic diameter thresholds for early detection of thoracic aortic dissection and aneurysm: Analysis in the UK Biobank
Paliwal, N.; Henry, A.; Finan, C.; Davies, R. H.; Lumbers, R.; Tsui, J.; Hughes, A.; Williams, B.; Hingorani, A. D.
Show abstract
Background & PurposeClinical guidelines recommend using an absolute ascending aortic diameter (AAD) cutoff of 4.5 cm for monitoring and 5.5 cm for surgery in people at risk of thoracic aortic dissection. However, AAD varies with age, sex, height and body surface area (BSA). Using imaging data from the UK Biobank, we investigated different AAD cutoffs in the prediction of aortic dissection or aneurysm based on normal population variation in AAD, with and without adjustment for age, sex, height and BSA. MethodsUsing cardiac magnetic resonance (CMR) images of UK Biobank participants, we applied a pre-trained neural network to segment and measure AAD. We evaluated four approaches to predict a subsequent clinical diagnosis of thoracic aortic dissection or presence of a thoracic aneurysm. We evaluated (i) the performance of the guideline endorsed AAD cutoff of 4.5 cm, and (ii) cutoffs based on the standardized deviation from the population mean aortic diameter (Z-score): a) without accounting for age, sex or anthropometric measures (ZAAD); b) accounting for age, height, and sex (ZH) and c) accounting for age, body surface area (BSA) and sex (ZBSA). We assessed performance using the detection rate (DR) and false positive rate (FPR). ResultsWe measured AAD from CMR images of 77,527 participants from UK Biobank, among whom there were 72 subsequent diagnoses of thoracic dissection or aneurysm (incidence rate [~]0.1%, approximately 1 in 1100). The AAD was 4.2 cm (SD 0.6) in affected individuals and 3.3 cm (SD 0.4) in unaffected individuals (p<0.001). The guideline endorsed 4.5 cm absolute AAD cutoff had a DR of 25% at a 0.3% FPR. A cutoff of ZAAD>2 detected 57% of affected individuals at a 3% FPR, while ZH>2 and ZBSA>2 had DRs of 53% and 47% respectively, with FPRs of 4% and 2%, respectively. The area under the ROC curve (AUC) was 0.90 for ZAAD, 0.84 for ZH and 0.83 for ZBSA. ConclusionThe current guideline-recommended absolute AAD cutoff of 4.5 cm has a low FPR but a low DR, missing nearly three-quarters of individuals who later developed thoracic aneurysm or dissection. Z-score-based approaches, particularly the ZAAD, improve the DR at the expense of a higher FPR. These findings support the consideration of population-derived Z-scores in clinical monitoring and risk stratification for thoracic aortas at risk of dissection.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Improved Hemodynamic Performance and Reduced Paravalvular Regurgitation with the SAPIEN 3 Ultra RESILIA Valve: A Propensity-Matched Single-Center TAVR Study 94%
- Fairness in Cardiac Magnetic Resonance Imaging: Assessing sex and racial bias in deep learning-based segmentation 94%
- Algorithm for Predicting Valvular Heart Disease from Heart Sounds in an Unselected Cohort 93%
Similar papers in this journal
- Artificial intelligence of arterial Doppler waveforms to predict major adverse outcomes among patients evaluated for peripheral artery disease 94%
- Prognostic Value of Patient-Reported Outcomes in Predicting Long-term Mortality after Transcatheter Aortic Valve Replacement (TAVR) 93%
- Right Heart Remodeling After Pulmonary Valve Replacement in Patients with Pulmonary Atresia or Critical Stenosis with Intact Ventricular Septum 93%
Similar papers in this journal
- Development of a Novel Index to Characterise Arterial Dynamics Using Ultrasound Imaging 94%
- Identification of Novel Genetic Susceptibility Loci for Thoracic and Abdominal Aortic Aneurysms Via Genome-Wide Association Study Using the UK Biobank Cohort 94%
- Genetic ablation of serotonin receptor 2B improves aortic valve hemodynamics in a high-cholesterol diet mouse model 93%
Similar papers in this journal
- Transcatheter or Surgical Aortic Valve Replacement in Patients with Severe Aortic Stenosis and Small Aortic Annulus: A Randomized Clinical Trial 95%
- Second Heart Field-derived Cells Contribute to Angiotensin II-mediated Ascending Aortopathies 93%
- Prevalence of Coronary Atherosclerosis in Master Female Endurance Athletes 93%
Similar papers in this journal
- Ticagrelor vs Clopidogrel: the Impact of Platelet Inhibition on Cerebrovascular Microembolic Events during TAVR 94%
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 94%
- Sex-Related Outcomes of Transcatheter Aortic Valve Implantation with Self-Expanding or Balloon-Expandable Valves: Insights from the OPERA-TAVI Registry 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.