In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part II: Effects on Leaflet Mechanics, Hemodynamics, and Stent Deflection Contributing to Thrombogenic Risk and Structural Degeneration
Boxwell, S.; Cahalane, R. M. E.; Armfield, D.; Hickey, W.; Cook, S.; Kelly, P.; Cardiff, P.; McNamara, L.
Show abstract
Background and ObjectivesTranscatheter aortic valve implantation (TAVI) is the leading treatment for aortic stenosis. Self-expanding transcatheter heart valves (THVs) are oversized to prevent paravalvular leakage and then deployed over the diseased native valve. However, this can result in incomplete expansion and elliptical deployment, which may influence thrombogenic risk and structural degeneration, although this is not fully understood. MethodsIn this study, we utilized a validated in silico framework to assess the impact of THV oversizing and ellipticity on leaflet mechanics, hemodynamic shear stress and stent deformation, which are indicators of structural degeneration and thrombogenicity. We simulated self-expansion of a deformable THV stent within an idealized aortic annulus, applied pulsatile loading conditions representative of the cardiac cycle and then evaluated post-deployment frame deformation, leaflet mechanics, hemodynamics and stent fatigue. ResultsWe predicted stent-frame decoupling of the supra-annular THV, with increased expansion and circularity at the functional valve level compared to the inflow. Maximal oversizing of the THV reduced valve expansion at the supra-annular valve level (< 90% expansion), which increased leaflet coaptation and pinwheeling, but reduced peak leaflet stresses and stent deflection. Maximal oversizing also altered hemodynamics, causing early mainstream flow separation, which increased leaflet oscillatory shear and viscous shear stress downstream of the THV, potentially increasing thrombogenic risk and promoting tissue degeneration. THV ellipticity induced heterogenous stent deflections, leading to variable leaflet stress distributions and coaptation mismatch. ConclusionWe propose that flexible THV stents may mitigate adverse effects of elliptical deployment and emphasize the importance of assessing THV expansion through fluoroscopy and considering post-TAVI balloon-dilatation to increase expansion and improve long-term functional valve performance.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Deployment of a digital twin using the coupled momentum method for fluid-structure interaction: a case study for aortic aneurysm 97%
- Hemodynamics Indicates Differences Between Patients With And Without A Stroke Outcome After Left Ventricular Assist Device Implantation 96%
- Patient-specific analysis of bicuspid aortic valve hemodynamics using a fully coupled fluid-structure interaction (FSI) model 96%
Similar papers in this journal
- A Computational Growth Framework for Biological Tissues: Application to Growth of Aortic Root Aneurysm Repaired by the V-shape Surgery 95%
- An Investigation into Patient-Specific 3D Printed Titanium Stents and the use of Etching to Overcome Selective Laser Melting Design Constraints. 94%
- Air leaks: stapling affects porcine lungs biomechanics 92%
Similar papers in this journal
- Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis 98%
- Impact of residual intimal flap displacement post-TEVAR on TBAD haemodynamics in compliant, patient-specific CFD simulations informed by MRI 97%
- Quantitative Assessment of Aortic Hemodynamics for Varying Left Ventricular Assist Device Outflow Graft Angles and Flow Pulsation 96%
Similar papers in this journal
- Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation: A finite element modeling study. 97%
- A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: Design, Fabrication, and Physiological relevancy 96%
- Ventricular anatomical complexity and gender differences impact predictions from computational models 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.