Back

In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part II: Effects on Leaflet Mechanics, Hemodynamics, and Stent Deflection Contributing to Thrombogenic Risk and Structural Degeneration

Boxwell, S.; Cahalane, R. M. E.; Armfield, D.; Hickey, W.; Cook, S.; Kelly, P.; Cardiff, P.; McNamara, L.

2025-09-27 cardiovascular medicine
10.1101/2025.09.25.25336635 medRxiv
Show abstract

Background and ObjectivesTranscatheter aortic valve implantation (TAVI) is the leading treatment for aortic stenosis. Self-expanding transcatheter heart valves (THVs) are oversized to prevent paravalvular leakage and then deployed over the diseased native valve. However, this can result in incomplete expansion and elliptical deployment, which may influence thrombogenic risk and structural degeneration, although this is not fully understood. MethodsIn this study, we utilized a validated in silico framework to assess the impact of THV oversizing and ellipticity on leaflet mechanics, hemodynamic shear stress and stent deformation, which are indicators of structural degeneration and thrombogenicity. We simulated self-expansion of a deformable THV stent within an idealized aortic annulus, applied pulsatile loading conditions representative of the cardiac cycle and then evaluated post-deployment frame deformation, leaflet mechanics, hemodynamics and stent fatigue. ResultsWe predicted stent-frame decoupling of the supra-annular THV, with increased expansion and circularity at the functional valve level compared to the inflow. Maximal oversizing of the THV reduced valve expansion at the supra-annular valve level (< 90% expansion), which increased leaflet coaptation and pinwheeling, but reduced peak leaflet stresses and stent deflection. Maximal oversizing also altered hemodynamics, causing early mainstream flow separation, which increased leaflet oscillatory shear and viscous shear stress downstream of the THV, potentially increasing thrombogenic risk and promoting tissue degeneration. THV ellipticity induced heterogenous stent deflections, leading to variable leaflet stress distributions and coaptation mismatch. ConclusionWe propose that flexible THV stents may mitigate adverse effects of elliptical deployment and emphasize the importance of assessing THV expansion through fluoroscopy and considering post-TAVI balloon-dilatation to increase expansion and improve long-term functional valve performance.

Published in Computer Methods and Programs in Biomedicine (predicted rank #4) · training set

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.