Sensor Estimated Home 6-Minute Walk Distance and Cardiac Effort in Pulmonary Hypertension and Heart Failure
Lachant, D.; Agarwal, N.; Ceruolo, M.; Alphonse, S. A.; Meyer, B. M.; Gamboa, K. M.; Depetrillo, P.; Slepian, M.; Patterson, H.; Slepian, B.; Norton, K.; Haight, D.; White, J. R.
Show abstract
BackgroundSensor-based estimation of six-minute walk distance and Cardiac Effort, number of heartbeats during the walk divided by distance walked, can be measured in the home. This study aimed to evaluate 1) the impact of walking course length on walk distance and Cardiac Effort, and 2) assess changes over time in a cohort of pulmonary hypertension and heart failure participants. MethodsThis was a prospective observational study conducted at two sites. Participants included pulmonary hypertension, heart failure, and healthy controls. All participants wore chest-based sensors capable of recording accelerometry and electrocardiographic data. At baseline visit, participants performed a six-minute walk test on both a 90-ft and a 30-ft course, separated by 30-minutes rest. Unsupervised home walk tests were performed on the following two days. All assessments were repeated eight weeks later. Walk distance and Cardiac Effort were measured using three methods: direct observation, lap count estimation, and a signal-derived method based on mean amplitude deviation. Comparisons between clinic and home-based measurements were made using paired t-tests, correlation analysis, and Bland-Altman testing. ResultsSixty-six participants were enrolled, including 42 with pulmonary hypertension or heart failure and 24 controls. Walk distance on the 90-foot course was 10.7 percent longer than on the 30-ft course. Home-based walk distance was similar to the 30-ft course but lower than the 90-ft course. Home Cardiac Effort was similar to in-clinic values and tracked with changes over time. ConclusionHome-based functional testing incorporating Cardiac Effort may offer a simple and effective remote metric to improve management of patients with heart failure.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Non-Invasive Scale Measurement of Cardiac Output Compared with the Gold-Standard Direct Fick Method: A Feasibility Study 95%
- iCPET calculator: a web-based application to standardize the calculation of alpha distensibility in patients with pulmonary arterial hypertension 95%
- Cardiac Output During Exercise: Thermodilution versus Direct Fick 94%
Similar papers in this journal
- Effects of interval treadmill training on spatiotemporal parameters in children with cerebral palsy: a machine learning approach 94%
- Lower Limb Vertical Stiffness and Frontal Plane Angular Impulse during Perturbation-Induced Single Limb Stance and Their Associations with Gait in Individuals Post-Stroke 91%
- Repeatability of gait of children with spastic cerebral palsy in different walking conditions 91%
Similar papers in this journal
- A sweat lactate sensor for detecting anaerobic threshold in patients with heart failure: a prospective clinical trial (LacS-001) 95%
- Ambulatory physiological measures obtained under naturalistic urban mobility conditions have acceptable reliability 93%
- The Ramp protocol: Uncovering individual differences in walking to an auditory beat using TeensyStep 93%
Similar papers in this journal
- Comparisons of Heart Rate Variability Responses to Head-up Tilt With and Without Abdominal and Lower-Extremity Compression in Healthy Young Individuals: A Randomized Crossover Study 92%
- Comparing algorithms for assessing upper limb use with inertial measurement units 91%
- Effective Assessments of a Short-duration Poor Posture on Upper Limb Muscle Fatigue before Physical Exercise 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.