Back

In vivo microvascular flow quantification in the mouse brain using Row-Column Ultrasound Localization Microscopy and directed graph analysis

Bertolo, A.; Ferrier, J.; Demeulenaere, O.; Dizeux, A.; Delaporte, T.; Osmanski, B.; Tanter, M.; Pernot, M.; Deffieux, T.

2025-09-29 bioengineering
10.1101/2025.09.17.676732 bioRxiv
Show abstract

Brain perfusion relies on a complex vascular network of arteries, veins, and capillaries to meet its constant demand for oxygen and nutrients. Disruption of this microvascular system is a hallmark of many neurological disorders, including small vessel disease, stroke, and brain tumors. As such, high-resolution in vivo imaging of cerebral microvascular flow and structure remains critical to understanding these pathologies. Among them, Ultrasound Localization Microscopy (ULM) allows noninvasive imaging of microvascular network at subwavelength resolution using injected microbubbles, but the approach remains mainly limited to 2D imaging with few volumetric implementations. In this study, we explore in vivo transcranial 3D ULM of the mouse brain using Row-Column Arrays (RCA) and introduce an analysis framework to build a flow-directed vascular graph from the ULM microbubble tracking data, allowing to differentiate between subgraphs of artery-like and vein-like vascular segments. Combined with Allen-based and Radius-based segmentations, we extract metrics including cerebral blood flow (CBF), microbubble (MB) velocity, flowrate, CBV fraction, vascular segment length and tortuosity in sixty-six different vascular classes. This high-sensitivity framework enables in vivo microvascular imaging and quantification in mice and provides a scalable platform for preclinical neurovascular studies in health and disease.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

1
IEEE Transactions on Medical Imaging
18 papers in training set
Top 0.1%
22.8%
2
Photoacoustics
11 papers in training set
Top 0.1%
10.2%
3
Biomedical Optics Express
84 papers in training set
Top 0.2%
6.9%
4
Optics Letters
13 papers in training set
Top 0.1%
6.9%
5
Scientific Reports
3102 papers in training set
Top 18%
6.4%
50% of probability mass above
6
Optica
25 papers in training set
Top 0.2%
4.9%
7
Advanced Science
249 papers in training set
Top 5%
3.7%
8
Light: Science & Applications
16 papers in training set
Top 0.1%
3.6%
9
Nature Communications
4913 papers in training set
Top 44%
2.6%
10
Journal of Biomedical Optics
25 papers in training set
Top 0.3%
2.1%
11
NeuroImage
813 papers in training set
Top 4%
1.8%
12
ACS Photonics
13 papers in training set
Top 0.2%
1.7%
13
Communications Biology
886 papers in training set
Top 9%
1.7%
14
Journal of Biophotonics
16 papers in training set
Top 0.4%
1.5%
15
PLOS ONE
4510 papers in training set
Top 58%
1.3%
16
Nano Letters
63 papers in training set
Top 2%
1.3%
17
APL Bioengineering
18 papers in training set
Top 0.2%
1.1%
18
Nature Biomedical Engineering
42 papers in training set
Top 2%
0.9%
19
Bioinformatics
1061 papers in training set
Top 9%
0.9%
20
Nature Methods
336 papers in training set
Top 6%
0.8%
21
IEEE Transactions on Biomedical Engineering
38 papers in training set
Top 0.8%
0.8%
22
Bioengineering
24 papers in training set
Top 1%
0.8%
23
Proceedings of the National Academy of Sciences
2130 papers in training set
Top 44%
0.8%
24
eLife
5422 papers in training set
Top 61%
0.7%
25
Frontiers in Physics
20 papers in training set
Top 1%
0.5%
26
Optics Express
23 papers in training set
Top 0.5%
0.5%