Carbonized rubber electrodes can cause a DC-offset in transcranial alternating current stimulation
Stecher, H. I.; Schulz, P.; Meiser, A.; Hunold, A.; Schellhorn, K.; Herrmann, C. S.
Show abstract
IntroductionCarbonized rubber electrodes are widely used in non-invasive brain stimulation studies. Due to their polarizable nature, however, they can cause a voltage offset, which might be problematic for concurrent EEG studies. ObjectiveIn this study, we aim to describe the voltage offset and ensure that the offset does not alter the intended waveform of applied stimulation. MethodsUsing data from 2 human studies and phantom measurements, which employed carbonized rubber electrodes, we quantify the magnitude and frequency of DC-offsets and contrast this against pilot-measurements using Ag/AGCl-electrodes. In a further phantom study, we record the offset-voltage that arises from the electrode/electrolyte interface and compare this to the voltage put out by the stimulation device. ResultsA non-zero voltage offset is present in all human and phantom studies employing carbonized rubber electrodes, while the offset using Ag/AgCl electrodes is close to zero. Direct measurements of the stimulator output in the presence of a measurable voltage offset at the stimulation electrodes shows that the offset originates from the electrodes and not from the current provided by the stimulation device. ConclusionUsing carbonized rubber-electrodes for stimulation can result in the emergence of a measurable voltage offset, due to their polarizable nature. We argue that this offset can be problematic in concurrent EEG recordings, as they pose the risk of amplifier saturation and distortions of the recorded stimulation waveform.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Microneurography as a Minimally Invasive Method to Assess Target Engagement During Neuromodulation 96%
- Towards adaptive deep brain stimulation: clinical and technical notes on a novel commercial device for chronic brain sensing 95%
- Multi-modal artificial dura for simultaneous large-scale optical access and large-scaleelectrophysiology in non-human primate cortex 94%
Similar papers in this journal
- Proper reference selection and re-referencing to mitigate bias in single pulse electrical stimulation data 96%
- The rt-TEP tool: real-time visualization of TMS-Evoked Potential to maximize cortical activation and minimize artifacts 96%
- A biophysically constrained brain connectivity model based on stimulation-evoked potentials. 94%
Similar papers in this journal
Similar papers in this journal
- Decoding Neural Activity in Sulcal and White Matter Areas of the Brain to Accurately Predict Individual Finger Movement and Tactile Stimuli of the Human Hand 95%
- Similarities Between Somatosensory Cortical Responses Induced via Natural Touch and Microstimulation in the Ventral Posterior Lateral Thalamus in Macaques 94%
- Endogenous signals during active movement predict deep brain stimulation evoked potential pathways: Results of a transfer function analysis 93%
Similar papers in this journal
- Characterising the contribution of auditory and somatosensory inputs to TMS-evoked potentials following stimulation of prefrontal, premotor and parietal cortex 94%
- Proof-of-Concept Validation of Noninvasive Detection of Cortical Spreading Depolarization with High Resolution Direct Current-Electroencephalography 94%
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.