Reliable Detection of SGLT2 Protein through Knockout-based Antibody Characterization and Optimized Procedures

Hirose, T.; Ito, H.; Endo, A.; Sato, S.; Takahashi, C.; Kaburagi, T.; Yano, K.; Ishikawa, R.; Kamada, A.; Oba-Yabana, I.; Satoh, M.; Morozumi, K.; Kaiho, Y.; Nakamura, Y.; Kamijo, K.; Yumura, W.; Mori, T.

2025-09-01 molecular biology
10.1101/2025.08.31.672288 bioRxiv
Show abstract

IntroductionSodium-glucose cotransporter 2 (SGLT2) is a key mediator of renal glucose reabsorption. Its pharmacological inhibition exerts cardio- and reno-protective benefits. Despite widespread clinical interest, reliable detection of SGLT2 protein remains challenging due to concerns regarding the specificity of available antibodies. MethodsThis study assessed the specificity of eight commercially available anti-SGLT2 antibodies by immunohistochemistry and Western blotting. Genetically engineered Sglt2-deficient mice and rats, generated via clustered regularly interspaced short palindromic repeats/CRISPR-associated protein 9 (CRISPR/Cas9) technology, were employed as definitive negative controls. Additionally, human kidney tissues, including renal cell carcinoma samples, were analyzed. ResultsAmong the antibodies tested, few exhibited robust specificity, characterized by substantial immunostaining with minimal background in wild-type kidney tissues and complete absence of staining in Sglt2-deficient samples. In renal cell carcinoma samples, a validated antibody detected SGLT2 immunostaining in proximal tubules of non-tumor regions but not in tumor areas. Subcellular localization studies revealed that SGLT2 was enriched within proximal tubular microvilli, partially overlapping with its co-factor PDZK1IP1 (MAP17). LRP2 (megalin) and NHE3 were placed at the microvillar base and did not colocalize with SGLT2. Western blotting identified a specific SGLT2 band at approximately 55 kDa in kidney lysates using several antibodies under optimized procedures. This band was shifted to approximately 45 kDa after enzymatic removal of N-linked glycans. One antibody detected a weak band at the same molecular mass even in kidney lysates from Sglt2-deficient rodents. ConclusionsConsiderable variability exists in the specificity of commercially available anti-SGLT2 antibodies. Only a limited number of antibodies are suitable for reliable detection of SGLT2 in rodent and human samples. Rigorous antibody characterization, including the use of knockout controls and optimized experimental conditions, is essential to ensure reproducibility and prevent misinterpretation in studies investigating the biological and pathophysiological roles of SGLT2.

Published in Hypertension (predicted rank #12) · training set

Matching journals

The top 6 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.