Dosimetric advantage of ring-mounted Halcyon linac in radiation therapy for lung tumors
Yang, S.; Xu, Y.
Show abstract
ObjectiveTo systematically compare the dosimetric performance of two radiotherapy devices, Halcyon and TrueBeam, in intensity-modulated radiotherapy (IMRT) plans for non-small cell lung cancer (NSCLC), providing a reference for hospitals to optimize NSCLC radiotherapy based on different devices. Materials and MethodsA retrospective analysis was conducted on 102 NSCLC patients who received curative radiotherapy. All initial plans were designed on the Eclipse 15.6 system based on TrueBeam parameters (6MV FF photon beam, IMRT, dose grid of 2.5mm). New plans were re-optimized using Halcyon parameters while maintaining the same field directions and other parameters. The comparison indicators included: planning target volume (PTV) dose metrics ([Formula], D2%, D98%, Dmean, V98%, conformity index CI, homogeneity index HI); dose metrics for organs at risk (OARs) (Lungs: V5-V60, MLD; Heart: V5-V60, Dmean; remaining normal tissues NT: V5-V30); monitor units (MUs) counts and plan complexity index (PCI). Differences were analyzed using paired t-tests or Wilcoxon tests in SPSS 27.0, and the correlation between MUs and PCI was assessed. ResultsThe PTV conformity index (CI) of Halcyon plans was significantly superior to that of TrueBeam (0.75{+/-}0.12 vs. 0.73{+/-}0.12, P<0.001). Halcyons [Formula] was higher than TrueBeam (6555.20{+/-}117.50 cGy vs. 6525.20{+/-}99.38 cGy, P<0.001), and V98% was slightly lower than TrueBeam (95.83{+/-}11.74% vs. 95.99{+/-}11.38%, P=0.046). There were no statistically significant differences in D2%, D98%, Dmean, and HI (P>0.05). Halcyon significantly reduced the volume of lungs, heart, and other normal tissues exposed to low and intermediate doses and lowered the mean lung dose (P<0.001). Halcyons MUs were significantly higher than TrueBeams (1323.1{+/-}374.91 vs. 1121.1{+/-}384.84, P<0.001), but its PCI was significantly lower than TrueBeams (0.09{+/-}0.03 vs. 0.17{+/-}0.05, P<0.001), indicating that Halcyon plans are more complex. The correlation between PCI and MUs was weak for Halcyon (R2=0.07), while the correlation was stronger for TrueBeam (R2=0.54). ConclusionCompared to TrueBeam, Halcyon demonstrated significant dosimetric advantages: superior target volume dose conformity and effective reduction in the volume of normal tissues (lung, heart, and remaining tissues) exposed to low and intermediate doses, especially in large PTV volumes where low-dose protection for NT was more significant. Although Halcyon plans are more complex and involve higher MUs, the complexity has a lower dependency on MUs, showing greater stability. Halcyon offers a safer treatment device choice for lung cancer patients who require precise dose control and low-dose protection.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Comprehensive Quantitative Evaluation of Inter-observer Delineation Performance of MR-guided Delineation of Oropharyngeal Gross Tumor Volumes and High-risk Clinical Target Therapy: An R-IDEAL Stage 0 Prospective Study 96%
- Cluster-Based Toxicity Estimation of Osteoradionecrosis via Unsupervised Machine Learning: Moving Beyond Single Dose-Parameter Normal Tissue Complication Probability by Using Whole Dose-Volume Histograms for Cohort Risk Stratification 96%
- Clinical Impact of Contouring Variability for Prostate Cancer Tumor Boost 96%
Similar papers in this journal
- Evaluation of indirect damage and damage saturation effects in dose-response curves of hypofractionated radiotherapy of early-stage NSCLC and brain metastases 97%
- First demonstration of the FLASH effect with ultrahigh dose-rate high-energy X-rays 96%
- Dosimetric and biologic intercomparison between electron and proton FLASH beams 94%
Similar papers in this journal
- Personalized volume-deescalated elective nodal irradiation in oropharyngeal squamous cell carcinoma (DeEscO): a study protocol 94%
- Morphological changes after cranial fractionated photon radiotherapy: localized loss of white matter and grey matter volume with increasing dose 94%
- Detection of Alteration in Carotid Artery Volumetry Using Standard-of-care Computed Tomography Surveillance Scans Following Unilateral Radiation Therapy for Early-stage Tonsillar Squamous Cell Carcinoma Survivors: A Cross-Sectional Internally-Matched Carotid Isodose Analysis 94%
Similar papers in this journal
- Standardising Breast Radiotherapy Structure Naming Conventions: A Machine Learning Approach 97%
- Quality of life and patient-reported outcomes following proton therapy for oropharyngeal carcinoma: a systematic review 96%
- Effectiveness of FLASH vs conventional dose rate radiotherapy in a model of orthotopic, murine breast cancer 95%
Similar papers in this journal
- Cell lines of the same anatomic site and histologic type show large variability in intrinsic radiosensitivity and relative biological effectiveness to protons and carbon ions 95%
- Evaluation of inverse treatment planning for Gamma Knife radiosurgery using fMRI brain activation maps as organs at risk 93%
- Non-Invasive monitoring of normal tissue radiation damage using quantitative ultrasound spectroscopy 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.