Assessing Body Composition via a Smartphone Computer Vision Application: Reliable but Biased Compared to BODPOD and InBody
Sisohor, J.; Ambegaonkar, J.; Lindsey, B.; Shaul, Y.; Martin, J.
Show abstract
Accurate assessment of body composition is essential for monitoring health status, fitness progress, and disease risk. Traditional methods such as air displacement plethysmography (BODPOD) and bioelectrical impedance analysis (BIA) are widely used to estimate body fat percentage (BF%), fat mass (FM), and fat-free mass (FFM), but can be costly or inaccessible. Smartphone applications utilizing computer vision (CV) offer a promising alternative. This study evaluated the agreement and test-retest reliability of a smartphone-based CV application (CVapp) compared to BODPOD and the InBody BIA device. Forty-nine adults (ages 18-70; 29 females, 27 racial and ethnic minority participants) completed two consecutive measurements using BODPOD, InBody, and CVapp in a single session. Differences in BF%, FM, and FFM estimates were analyzed using repeated-measures ANOVA. Agreement metrics included mean absolute error (MAE), root mean square error (RMSE), concordance correlation coefficients (CCC), and Bland-Altman analysis. Subgroup analyses examined differences by sex and minority status. The CVapp yielded significantly higher BF% (mean=+2.2%, p=0.004) and FM (+1.5 kg, p=0.015) compared to BODPOD, and lower FFM than InBody (mean=-1.84 kg, p=0.043). The CVapp agreement with BODPOD (MAE=4.0, RMSE=5.0, CCC=0.86) was lower than with the InBody (MAE=3.3, RMSE=4.3, CCC=0.89), with wider limits of agreement. All methods showed excellent test-retest reliability (ICC>0.99). A significant SexxMethod interaction was observed for BF% (p<0.001), FM (p<0.001), and FFM (p=0.013), with females showing greater overestimation of BF% (mean=+3.9%) and FM (mean=+2.7kg, p<0.001), and underestimation of FFM (mean=-2.5kg, p<0.001) by the CVapp. Among minority participants, BF% and FM estimates from the CVapp were significantly higher than BODPOD (mean=+2.7%, p=0.009; mean=+1.8kg, p=0.031), and FFM was lower (mean=-1.8kg, p=0.035), with significant MethodxMinority Group interactions for FM and FFM (p<0.03). While the CVapp was reliable, its estimates differed from other common body composition methods and revealed population-specific biases, highlighting the need for more accurate and equitable algorithms.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Estimation equation of limb lean soft tissue mass in Asian athletes using bioelectrical impedance analysis 96%
- Longitudinal changes in anthropometric, physiological, and physical qualities of international women’s rugby league players 95%
- Validity and reliability of a new whole room indirect calorimeter to assess metabolic response to small-calorie loads 94%
Similar papers in this journal
- Joint associations between objectively measured physical activity volume and intensity with body-fatness. The Fenland Study 91%
- Evidence for protein leverage on Total Energy Intake, but not Body Mass Index, in a large cohort of older adults 89%
- Obesity, walking pace and risk of severe COVID-19: Analysis of UK Biobank 88%
Similar papers in this journal
- Association of Muscle Strength to Body Composition Measures using DXA, D 3 Cr, and BIA in Collegiate Athletes 96%
- Ambulatory physiological measures obtained under naturalistic urban mobility conditions have acceptable reliability 93%
- Joint contact forces during barefoot, minimal and conventional shod running are highly individual 92%
Similar papers in this journal
- Machine learning-based equations for improved body composition estimation in Indian adults 96%
- How can digital citizen science approaches improve ethical smartphone use surveillance among youth: traditional surveys versus ecological momentary assessments 91%
- Automated Image Transcription for Perinatal Blood Pressure Monitoring Using Mobile Health Technology 90%
Similar papers in this journal
- Protocol for a prospective cohort study on the feasibility of application of nutritional ultrasound in the diagnosis and follow-up of patients with nutritional risk at hospital discharge: Study on body composition and function (DRECO) 94%
- Reference values and validation of the 1-min sit-to-stand test in healthy 5- to 16-year-old youth: a cross-sectional study 93%
- Translation, adaptation, and measurement properties of the Muscle-Strengthening Exercise Questionnaire among university students in Indonesia 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.