Back

Radiation Free Percutaneous Nephrolithotomy (PCNL) is Not Always Feasible comparative prospective trial

Sward, N. N.; Galvez, A.; Hull, R.; Girgiss, J.; Katz, J.; Roberts, J.; Sheetz, T.; Griffiths, L.; Ugander, M.; Sur, R. L.

2025-07-30 urology
10.1101/2025.07.30.25332444 medRxiv
Show abstract

Introduction and ObjectivePercutaneous nephrolithotomy (PCNL) is a minimally invasive procedure for kidney stone removal traditionally guided by fluoroscopy. This study aimed to evaluate the feasibility and outcomes of radiation-free PCNL using ultrasound alone compared to standard fluoroscopy-guided PCNL. MethodsA total of 63 PCNL cases were eligible for radiation-free PCNL, but 27 were excluded (intra-operatively aborted, ureteroscopy performed instead, pre-operative complex anatomy). Of the remaining 36 cases eligible for radiation-free PCNL, 11 were converted intra-operatively to fluoroscopic based PCNL. Post-operative CT imaging was available for only 16 of the 25 radiation-free PCNL cases and 4 of the 11 converted cases. We designated these 16 prospective radiation-free PCNL cases (2024-2025) as Group A. For comparison purposes we identified a historical case-matched cohort of 150 PCNLs. Of these 67 were excluded (similar reasons) leaving 83 retrospective fluoroscopy-guided PCNL cases (2022-2024) called Group B. The primary outcome was stone-free rate (SFR), assessed post-operatively by non-contrast CT (2-3 mm slices). Secondary outcomes included estimated blood loss (EBL), complication rates (Clavien-Dindo), and post-operative stone events. ResultsThe median pre-operative stone burden was 35 mm in Group A and 27 mm in Group B and C [p=0.3]. SFR (Grade A) was comparable across Groups A, B, and C [38%, 30%, 25% respectively (p = 0.8)]. No differences were observed in complications or secondary outcomes. ConclusionsRadiation-free PCNL is feasible and yields comparable outcomes to standard fluoroscopy-guided PCNL, offering a promising method to reduce radiation exposure without compromising surgical success. However, we identified a consistent theme of poor visualization that led to large proportion of cases requiring conversion to fluoroscopy. Innovation directed towards improving tool echogenicity is key to diffusing this technique.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.