Feasibility of Longitudinal Relaxation Rate Mapping with Non-Cartesian Sampling and Compressed Sensing on a 1.5T MR-Linac
McCullum, L.; van Rijssel, M. J.; Hwang, K.-P.; Ding, Y.; Tang, C.; Hassanzadeh, C.; Yang, J.; Balter, P. A.; Wang, J.; Fuller, C. D.; Subashi, E.
Show abstract
BackgroundQuantitative mapping of the longitudinal relaxation rate (R1=1/T1) is a major building block for several multiparametric MRI protocols intended for adaptive radiation therapy planning. The implementation of these protocols is challenging in anatomical sites that experience large physiological motion. PurposeTo implement and validate a motion-resolved quantitative T1 mapping method on a 1.5T MR-Linac that combines non-Cartesian k-space sampling trajectories with compressed sensing (CS) reconstruction techniques. MethodsFour 3D non-Cartesian k-space trajectories were evaluated: radial and stack-of-stars sampling using half- and full-spoke coverage. A variable flip angle acquisition was performed using the spoiled gradient-echo sequence, and T1 mapping was validated using two standard phantoms. Gradient delay timing was optimized empirically to minimize trajectory-induced artifacts. Eight compressed sensing reconstruction strategies were tested using spatial and spatiotemporal regularization operators. Reconstructions were evaluated across multiple implementation parameters and ranked based on spatial resolution, bias, and variability. In vivo studies included one healthy volunteer and one patient undergoing radiotherapy to a target in the kidney. Motion-resolved imaging was performed using respiratory self-gating and phase-sorted reconstruction. ResultsAll non-Cartesian trajectories demonstrated high repeatability and low longitudinal bias in phantom studies, with coefficients of variation below 3.3%. Radial half-spoke sampling achieved the shortest scan times and highest agreement with Cartesian benchmarks. Reconstruction methods incorporating spatiotemporal regularization maintained spatial resolution and quantitative accuracy across undersampling factors up to 20-fold. In human subjects, non-Cartesian T1 mapping provided improved accuracy and reduced variability in mobile abdominal tissues compared to Cartesian acquisitions, particularly in the kidney cortex and medulla, where motion artifacts led to overestimation and higher variance in the reference method. ConclusionsT1 mapping using non-Cartesian trajectories and compressed sensing reconstruction is feasible on a 1.5T MR-Linac. The proposed approach enables accurate, motion-resolved quantitative imaging within clinically practical acquisition times. These results support integration of quantitative T1 mapping into adaptive MR-guided radiotherapy workflows and establish a foundation for future development of multiparametric imaging and response-adaptive treatment strategies.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling 96%
- Vendor-neutral sequences (VENUS) and fully transparent workflows improve inter-vendor reproducibility of quantitative MRI 95%
- SNR-Efficient Whole-Brain Pseudo-Continuous Arterial Spin Labeling Perfusion Imaging at 7 Tesla 95%
Similar papers in this journal
- Improved 7 Tesla Transmit Field Homogeneity with Reduced Electromagnetic Power Deposition Using Coupled Tic Tac Toe Antennas 95%
- Non-Invasive Perfusion MR Imaging of the Human Brain via Breath-Holding 93%
- An AI-based segmentation and analysis pipeline for high-field MR monitoring of cerebral organoids 93%
Similar papers in this journal
- Quality Assurance Assessment of Intra-Acquisition Diffusion-Weighted and T2-Weighted Magnetic Resonance Imaging Registration and Contour Propagation for Head and Neck Cancer Radiotherapy 95%
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 94%
- Necessity and Impact of Specialization of Large Foundation Model for Medical Segmentation Tasks 93%
Similar papers in this journal
Similar papers in this journal
- Comprehensive Quantitative Evaluation of Inter-observer Delineation Performance of MR-guided Delineation of Oropharyngeal Gross Tumor Volumes and High-risk Clinical Target Therapy: An R-IDEAL Stage 0 Prospective Study 92%
- Initial Feasibility and Clinical Implementation of Daily MR-guided Adaptive Head and Neck Cancer Radiotherapy on a 1.5T MR-Linac System: Prospective R-IDEAL 2a/2b Systematic Clinical Evaluation of Technical Innovation 91%
- Noninvasive Quantification of Radiation-Induced Lung Injury using a Targeted Molecular Imaging Probe 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.