RV IsoMax: Development of a web-based single-beat analysis tool for the determination of RV-PA coupling.

Agarwal, S.; Miller, A.; Hsu, S.; Rahaghi, F. N.; Visovatti, S. H.; Vanderpool, R. R.

2025-07-22 cardiovascular medicine
10.1101/2025.07.21.25331587 medRxiv
Show abstract

BackgroundRight ventricular (RV) function significantly associates with mortality in pulmonary hypertension. Single-beat methods allow for clinical estimates of max isovolumetric pressure (Pmax) but have not been widely adopted due to inter-user and inter-method variability and center specific implementation of methods. The study aim was to develop a web-based analysis single-beat analysis program that optimizes single-beat Pmax estimates while reducing inter-user variability. MethodsParticipants with a right heart catheterization were retrospectively identified from The Ohio State University Pulmonary Hypertension Registry. Right ventricular waveforms were digitized. The single-beat analysis program, RV IsoMax, was developed in R/RShiny to semi-automatically estimate the maximum isovolumetric pressure (Pmax). RV IsoMax results were compared to the popular 2nd derivative single-beat method. Interclass correlation coefficients were calculated for interobserver and inter-method variability in Pmax estimates. ResultsThe RV IsoMax method was tested across the spectrum of PH in participants with PH (n=45) and without PH (n=10). For the RV IsoMax method, there was no significant bias in Pmax estimates between observers (intraclass correlation coefficient: 0.96). In an inter-method comparison, the 2nd derivative method significantly underestimated Pmax compared to RV IsoMax with a bias of 24 mmHg (intraclass correlation coefficient to 0.69). The variability between methods persists into end-systolic elastance (Ees) and RV-PA coupling (Ees/Ea). ConclusionsThe interactive user interface of the RV IsoMax application allows the user to semi-automatically calculate and explore variability in Pmax estimates. Significant differences in Pmax estimates between single-beat methods indicate their cut-off values cannot be used interchangeably. CLINICAL PERSPECTIVE What is new?O_LIRV IsoMax is the first publicly available web-based tool for the single-beat analysis of RV pressure waveforms available at: https://vanderpoolrr.shinyapps.io/RV_IsoMax/. C_LIO_LIRV IsoMax is a semi-automatic algorithm that has been implemented with an easy-to-use graphical user interface (GUI) that allows the user to inspect the goodness of the Pmax estimations, adjust as needed and download the results as an excel file. C_LIO_LIIn comparison to the 2nd derivative single-beat analysis method, the RV IsoMax algorithm utilizes smaller fitting regions focused on early isovolumetric contraction and late isovolumetric relaxation that maximizes Pmax while allowing for reduced inter-user variability. C_LI What are the clinical implications?O_LIThe web-based RV IsoMax app is a tool that can help facilitate the use of single-beat methods to determine RV-PA coupling in more clinical settings with standardized methods. C_LI

Matching journals

The top 8 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.