Cardiac Measurement Calculation on Point-of-Care Ultrasonography with Artificial Intelligence
Mercaldo, S. F.; Bizzo, B. C.; Sadore, T.; Halle, M. A.; MacDonald, A. L.; Newbury-Chaet, I.; L'Italien, E.; Schultz, A. S.; Tam, V.; Hegde, S. M.; Mangion, J. R.; Mehrotra, P.; Zhao, Q.; Wu, J.; Hillis, J.
Show abstract
IntroductionPoint-of-care ultrasonography (POCUS) enables clinicians to obtain critical diagnostic information at the bedside especially in resource limited settings. This information may include 2D cardiac quantitative data, although measuring the data manually can be time-consuming and subject to user experience. Artificial intelligence (AI) can potentially automate this quantification. This study assessed the interpretation of key cardiac measurements on POCUS images by an AI-enabled device (AISAP Cardio V1.0). MethodsThis retrospective diagnostic accuracy study included 200 POCUS cases from four hospitals (two in Israel and two in the United States). Each case was independently interpreted by three cardiologists and the device for seven measurements (left ventricular (LV) ejection fraction, inferior vena cava (IVC) maximal diameter, left atrial (LA) area, right atrial (RA) area, LV end diastolic diameter, right ventricular (RV) fractional area change and aortic root diameter). The endpoints were the root mean square error (RMSE) of the device compared to the average cardiologist measurement (LV ejection fraction and IVC maximal diameter were primary endpoints; the other measurements were secondary endpoints). Predefined passing criteria were based on the upper bounds of the RMSE 95% confidence intervals (CIs). The inter-cardiologist RMSE was also calculated for reference. ResultsThe device achieved the passing criteria for six of the seven measurements. While not achieving the passing criterion for RV fractional area change, it still achieved a better RMSE than the inter-cardiologist RMSE. The RMSE was 6.20% (95% CI: 5.57 to 6.83; inter-cardiologist RMSE of 8.23%) for LV ejection fraction, 0.25cm (95% CI: 0.20 to 0.29; 0.36cm) for IVC maximal diameter, 2.39cm2 (95% CI: 1.96 to 2.82; 4.39cm2) for LA area, 2.11cm2 (95% CI: 1.75 to 2.47; 3.49cm2) for RA area, 5.06mm (95% CI: 4.58 to 5.55; 4.67mm) for LV end diastolic diameter, 10.17% (95% CI: 9.01 to 11.33; 14.12%) for RV fractional area change and 0.19cm (95% CI: 0.16 to 0.21; 0.24cm) for aortic root diameter. DiscussionThe device accurately calculated these cardiac measurements especially when benchmarked against inter-cardiologist variability. Its use could assist clinicians who utilize POCUS and better enable their clinical decision-making.
Matching journals
The top 10 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Natural Language Processing for the Ascertainment and Phenotyping of Left Ventricular Hypertrophy and Hypertrophic Cardiomyopathy on Echocardiogram Reports 94%
- Prognostic value of compact myocardial thinning in patients with left ventricular non-compaction 94%
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 94%
Similar papers in this journal
- Non-Invasive Scale Measurement of Cardiac Output Compared with the Gold-Standard Direct Fick Method: A Feasibility Study 95%
- Patient Screening for Self-Expanding Percutaneous Pulmonary Valves using Virtual Reality 95%
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 94%
Similar papers in this journal
- Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation: A finite element modeling study. 95%
- {-}CardiOvascular examination in awake Orangutans (Pongo pygmaeus pygmaeus): Low-stress Echocardiography including Speckle Tracking imaging (the COOLEST method) 95%
- A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: Design, Fabrication, and Physiological relevancy 93%
Similar papers in this journal
- Automated Echocardiographic Detection of Mitral Valve Prolapse and Mitral Regurgitation with Video-based Artificial Intelligence Algorithms 95%
- Deep Learning-Based Multi-View Echocardiographic Framework for Comprehensive Diagnosis of Pericardial Disease 94%
- Simple Models Versus Deep Learning in Detecting Low Ejection Fraction From The Electrocardiogram 93%
Similar papers in this journal
- Algorithm for Predicting Valvular Heart Disease from Heart Sounds in an Unselected Cohort 95%
- Fairness in Cardiac Magnetic Resonance Imaging: Assessing sex and racial bias in deep learning-based segmentation 94%
- Deep learning-based end-to-end automated stenosis classification and localization on catheter coronary angiography 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.