Robust-tedana: An automated denoising pipeline for multi-echo fMRI data
Tahayori, B.; Smith, R. E.; Vaughan, D. N.; Tailby, C.; Handwerker, D. A.; Pierre, E. Y.; Jackson, G. D.; Abbott, D. F.
Show abstract
Multi-echo functional Magnetic Resonance Imaging (fMRI) data are acquired by recording image volumes at multiple echo times and can be used to improve the separation of neural activity from noise. TE-Dependent ANAlysis (tedana) is an open-source software tailored to denoising of multi-echo fMRI data. The efficacy of denoising can however be inconsistent, often necessitating manual inspection that precludes its application in large-scale studies where processing is ideally fully automated. Here, we introduce Robusttedana, an optimised denoising pipeline that achieves adequate results at both single-subject and group level. Robust-tedana incorporates Marchenko-Pastur Principal Component Analysis (MPPCA) for effective thermal noise reduction, robust independent component analysis for stabilised signal decomposition, and a modified component classification process. We evaluated its performance on Multi-Band Multi-Echo (MBME) language-task fMRI data from the Australian Epilepsy Project (AEP) using objective measures, comparing to conventional fMRI analysis with and without multi-echo-based denoising. Experts manual evaluation was undertaken on a subset of these data to validate the objective measures. The proposed pipeline both mitigates the prevalence of erroneous attenuation of genuine task activation due to instability of single-subject analysis, and increases the magnitude of group-wise effects. Robust-tedana therefore facilitates advanced analysis of MBME fMRI data in an automated pipeline, including for clinical research assessment of individuals.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Evaluating the effect of denoising submillimeter auditory fMRI data with NORDIC 97%
- A Set of FMRI Quality Control Tools in AFNI: Systematic, in-depth and interactive QC with afni_proc.py and more 97%
- The efficacy of resting-state fMRI denoising pipelines for motion correction and behavioural prediction. 97%
Similar papers in this journal
Similar papers in this journal
- The developing Human Connectome Project (dHCP) automated resting-state functional processing framework for newborn infants. 98%
- Comparing the efficacy of data-driven denoising methods for a multi-echo fMRI acquisition at 7T 97%
- Diffusion-Informed Spatial Smoothing of fMRI Data in White Matter Using Spectral Graph Filters 96%
Similar papers in this journal
- Assessing uncertainty in connective field estimations from resting state fMRI activity 96%
- A library for fMRI real-time processing systems in python (RTPSpy) with comprehensive online noise reduction, fast and accurate anatomical image processing, and online processing simulation 96%
- Early Stopping in Experimentation with Real-time Functional Magnetic Resonance Imaging Using a Modified Sequential Probability Ratio Test 96%
Similar papers in this journal