Back

Utility of 18F-Flurpiridaz PET Relative Flow Reserve in Differentiating Obstructive from Nonobstructive Coronary Artery Disease

Lopez, D. M.; Huck, D.; Divakaran, S.; Brown, J.; Weber, B.; Lemley, M.; Builoff, V.; Shanbhag, A.; Lan, Z.; Buckley, C.; Al-Mallah, M.; Dorbala, S.; Blankstein, R.; Slomka, P.; Di Carli, M.

2025-06-13 cardiovascular medicine
10.1101/2025.06.11.25329454 medRxiv
Show abstract

BackgroundAbsolute quantification of myocardial blood flow (MBF) on PET perfusion imaging improves the identification of coronary artery disease (CAD). However, distinguishing MBF impairment due to obstructive CAD from nonobstructive CAD remains challenging. We aimed to evaluate the incremental diagnostic value of PET-derived relative flow reserve (RFR) in the diagnosis of obstructive CAD. MethodsThis is a post hoc analysis of the multicenter phase-III trial of 18F-flurpiridaz PET (NCT01347710). Patients with available MBF quantification were included. Reduced stress MBF (sMBF) was defined as sMBF below the median (2.2 mL/min/g). Obstructive CAD on quantitative invasive coronary angiography (ICA) was defined as >70% stenosis. RFR was calculated as a ratio of the minimal segment sMBF over the highest reference vascular territory sMBF. RFR performance for predicting obstructive CAD was evaluated through Receiver Operating Characteristic (ROC) analysis and the net reclassification index (NRI) of multivariable regression models. ResultsThe study included 231 patients (71% male; 56% with established CAD) drawn from the original cohort of 755 trial participants. No patients had three-vessel CAD. In a per vessel-based analysis, 82% of vessels with reduced sMBF had no obstructive CAD on ICA. RFR was significantly lower for vessels with obstructive CAD (0.55 vs 0.80, p<0.0001). In vessels with reduced sMBF, RFR was independently associated with obstructive CAD even after accounting for sTPD and MFR (OR 3.08, 95% CI: 1.49-6.38; p = 0.002). While the addition of RFR did not significantly improve discrimination (AUC 0.806 vs. 0.822, p = 0.11), it significantly improved reclassification of vessels with and without obstructive CAD (NRI: 0.93, p < 0.0001). ConclusionsRFR provides complementary diagnostic information beyond existing PET parameters and may help refine the diagnosis of obstructive CAD in patients with reduced flows. Clinical PerspectiveA major diagnostic dilemma in cardiac PET/CT perfusion imaging is determining whether reductions in stress myocardial blood flow and/or myocardial flow reserve are caused by obstructive or nonobstructive coronary artery disease (CAD), leading to uncertainty about whether invasive angiography is needed. Our study demonstrates that incorporating PET-derived relative flow reserve (RFR) adds meaningful diagnostic information beyond existing PET perfusion and flow parameters. RFR does not substantially increase overall discrimination between obstructive and nonobstructive CAD, but it significantly improves reclassification of individual cases, indicating that RFR can help refine decision-making, particularly in borderline cases. These data suggest that selective integration of RFR with existing PET metrics could improve patient selection for invasive procedures and guide more targeted medical therapy for nonobstructive CAD. Future research is needed to confirm these findings across a broader patient population, including higher-risk cohorts and women, as well as with other PET radiotracers.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.