fMRI-Based CSF Flow Quantification Identifies Cardiac Pulsatility as the Dominant Driver Over Respiratory and Slow Vasomotion Cycles
Soderstrom, P.; Bjornfot, C.; Andersson, B. M.; Malm, J.; Eklund, A.; Wahlin, A.
Show abstract
PurposeCerebrospinal fluid (CSF) flow oscillations have emerged as a potentially important marker related to brain clearance, but their acquisition often relies on specialized imaging MRI sequences. The purpose of this work was to enable quantitative assessment of CSF flow associated with cardiac, respiratory, and slow-vasomotion cycles using widely available functional magnetic resonance imaging (fMRI) acquisitions. MethodsA method was developed to translate fMRI-derived CSF inflow signals into quantitative flow rates. This approach modelled the spin-history of an oscillating ensemble of molecules. Validation was performed using phantom experiments with oscillatory flow at cardiac-, respiratory-, and slow-vasomotion-like frequencies. The method was further applied to resting-state data from 48 older adults (68-82 years; 19 women) to characterize CSF flow at the foramen magnum. ResultsPhantom experiments demonstrated excellent correlations between estimated and true velocities for cardiac- and respiratory-like frequencies (r = 0.94 and 0.97, respectively) and moderate correlation for a slow-vasomotion-like frequency (r = 0.58). In the population cohort, median CSF stroke volumes were 0.86 [0.61, 1.17] mL for the cardiac cycle, 0.44 [0.25, 0.94] mL for the respiratory cycle, and 0.28 [0.14, 0.45] mL for the slow-vasomotion cycle. ConclusionThe proposed spin-history modeling method enabled quantitative estimation of CSF flow components using a conventional fMRI dataset and showed that the cardiac cycle dominates CSF motion at the foramen magnum.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Cerebrospinal Fluid Flow within Ventricles and Subarachnoid Space Evaluated by Velocity Selective Spin Labeling MRI 97%
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions 96%
- The potential for gas-free measurements of absolute oxygen metabolism during both baseline and activation states in the human brain 96%
Similar papers in this journal
- Increased Brain Volumetric Measurement Precision from Multi-Site 3D T1-weighted 3T Magnetic Resonance Imaging by Correcting Geometric Distortions 96%
- Tailored Magnetic Resonance Fingerprinting 96%
- Influence of preprocessing, distortion correction and cardiac triggering on the quality of diffusion MR images of spinal cord 94%
Similar papers in this journal
- Visual stimulus-evoked blood velocity responses in individual human posterior cerebral arteries measured with dynamic phase-contrast functional MR angiography 96%
- The Spatial Patterns and Determinants of Cerebrospinal Fluid Circulation in the Human Brain 96%
- Modeling dynamic inflow effects in fMRI to quantify cerebrospinal fluid flow 95%
Similar papers in this journal
- Early Stopping in Experimentation with Real-time Functional Magnetic Resonance Imaging Using a Modified Sequential Probability Ratio Test 95%
- Most small cerebral cortical veins demonstrate significant flow pulsatility: a human phase contrast MRI study at 7T 94%
- Quantitative evaluation of normal cerebrospinal fluid flow in the Sylvian aqueduct and perivascular spaces of the middle cerebral artery and circle of Willis via 2D phase-contrast MR imaging 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.